Mackie FRS1300 Скачать руководство пользователя страница 2

FRS SERIES AMPLIFIERS

FRS SERIES AMPLIFIERS

1.

  Read these instructions.  

2.

  Keep these instructions.

3.

  Heed all warnings.

4.

  Follow all instructions.

5.

  Do not use this apparatus near water.

6.

  Clean only with dry cloth.

7.

  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

8.

  Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

9.

  Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. 

A grounding-type plug has two blades and a third grounding prong. 

The wide blade or the third prong are provided for your safety. If the 

provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10.

 Protect the power cord from being walked on or pinched particularly at 

plugs, convenience receptacles, and the point where they exit from the 

apparatus.

11.

 Only use attachments/accessories specified by the manufacturer.

12.

 Use only with a cart, stand, tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. When a cart is used, use 

caution when moving the cart/apparatus combination to avoid injury 

from tip-over.

13.

 Unplug this apparatus during lightning storms or when unused for long 

periods of time.

14.

 Refer all servicing to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as power-

supply cord or plug is damaged, liquid has been spilled or objects have 

fallen into the apparatus, the apparatus has been exposed to rain or 

moisture, does not operate normally, or has been dropped.

15.

 This apparatus shall not be exposed to dripping or splashing, and no 

object filled with liquids, such as vases or beer glasses, shall be placed 

on the apparatus.

16.

 This apparatus has been designed with Class-I construction and must 

be connected to a mains socket outlet with a protective earthing con-

nection (the third grounding prong).

17.

 This apparatus has been equipped with an all-pole, rocker-style AC 

mains power switch. This switch is located on the front panel and 

should remain readily accessible to the user.

18.

 This apparatus does not exceed the Class A/Class B (whichever is 

applicable) limits for radio noise emissions from digital apparatus as 

set out in the radio interference regulations of the Canadian Department 

of Communications.

ATTENTION

 — 

Le présent appareil numérique n’émet pas de bruits 

radioélectriques dépassant las limites applicables aux appareils numériques de 

class A/de class B (selon le cas) prescrites dans le réglement sur le brouillage 

radioélectrique édicté par les ministere des communications du Canada.

19.

 Exposure to extremely high noise levels may cause permanent hearing 

loss. Individuals vary considerably in susceptibility to noise-induced 

hearing loss, but nearly everyone will lose some hearing if exposed to 

sufficiently intense noise for a period of time. The U.S. Government’s 

Occupational Safety and Health Administration (OSHA) has specified 

the permissible noise level exposures shown in the following chart.

  According to OSHA, any exposure in excess of these permissible limits 

could result in some hearing loss. To ensure against potentially danger-

ous exposure to high sound pressure levels, it is recommended that all 

persons exposed to equipment capable of producing high sound pres-

sure levels use hearing protectors while the equipment is in operation. 

Ear plugs or protectors in the ear canals or over the ears must be worn 

when operating the equipment in order to prevent permanent hearing 

loss if exposure is in excess of the limits set forth here. 

Important Safety Instructions

Duration Per Day 

 Sound Level dBA, 

Typical 

  In Hours 

Slow Response 

Example

 

90 

Duo in small club

 

92 

 

 

95 

Subway Train

 

97

 

100 

Very loud classical music

 

  1.5 

102

 

105 

Dave screaming at Steve about deadlines

 

0.5  

110

 

 0.25 or less 

115 

Loudest parts at a rock concert

WARNING — To reduce the risk of fire or 

electric shock, do not expose this apparatus 

to rain or moisture.

PORTABLE CART WARNING

Carts and stands - The

Component should be used

only with a cart or stand

that is recommended by

the manufacturer.

A Component and cart

combination should be

moved with care.  Quick

stops, excessive force, and

uneven surfaces may cause

the Component and cart

combination to overturn.

CAUTION    AVIS

RISK OF ELECTRIC 

SHOCK 

DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC

ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.  AUCUN

ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.  CONFIER

L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU

D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

   The lightning flash with arrowhead symbol within an equilateral 
triangle is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product's enclosure, that may be 
of sufficient magnitude to constitute a risk of electric shock to persons.

   Le symbole éclair avec point de flèche à l'intérieur d'un triangle 
équilatéral est utilisé pour alerter l'utilisateur de la présence à 
l'intérieur du coffret de "voltage dangereux" non isolé d'ampleur 
suffisante pour constituer un risque d'éléctrocution.

   The exclamation point within an equilateral triangle is intended to 
alert the user of the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the appliance.

   Le point d'exclamation à l'intérieur d'un triangle équilatéral est 
employé pour alerter les utilisateurs de la présence d'instructions 
importantes pour le fonctionnement et l'entretien (service) dans le 
livret d'instruction accompagnant l'appareil.

Содержание FRS1300

Страница 1: ...C 30Hz SPEAKER OUTPUTS PIN 1 1 PIN 1 2 1 1 PIN 2 2 PIN 1 1 FAST RECOVERY POWER AMPLIFIER THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR THE U S AND ICES 003 FOR CANADA OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION WARNING ...

Страница 2: ...eptibility to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a period of time The U S Government s Occupational Safety and Health Administration OSHA has specified the permissible noise level exposures shown in the following chart According to OSHA any exposure in excess of these permissible limits could result in some hearing los...

Страница 3: ...ING 12 REPAIR 13 APPENDIX B CONNECTIONS MATH AND STUFF 14 XLR CONNECTORS 14 1 4 TRS PHONE PLUGS AND JACKS 14 1 4 TS PHONE PLUGS AND JACKS 14 SPEAKONS 14 LOUDSPEAKER CABLE 14 LONGER LENGTHS 15 SPEAKER IMPEDANCES 15 APPENDIX C TECHNICAL INFO 16 SPECIFICATIONS 16 BLOCK DIAGRAM 17 DIMENSIONS 18 LIMITED WARRANTY 19 NeedhelpwithyournewFRSamplifier Visitwww mackie comandclickSupporttofind FAQs manuals ad...

Страница 4: ...transport ing FEATURES Professional lightweight power amplifier with high power low distortion design Fast Recovery circuitry for clean undistorted sound even at clipping Ultra light switching power supply for maxi mum efficiency and minimal heat Available in three powerful models with continuous power 4 ohms bridged of FRS 1300 1300 W FRS 1700 1660 W FRS 2800 2800 W Selectable dual mono stereo or...

Страница 5: ...ables to the speaker outputs either the bind ing posts or the Speakon connectors The binding post connectors are wired as fol lows Red hot speaker terminal Black cold speaker terminal The speakon connectors are wired as follows 1 hot speaker terminal 1 cold speaker terminal 5 In bridge mode if using the binding post out puts Ch 1 red post hot speaker terminal Ch 2 red post cold speaker terminal Do...

Страница 6: ...USE UNDESIRED OPERATION WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR FROM MIXING CONSOLE MONO OUT AMP MODE SWITCH MONO CH 1 AND CH 2 PLAYTHE SAME TO SPEAKERS OPTIONAL CONNECTION USING BINDING POSTS Passive ...

Страница 7: ...S PIN 1 1 PIN 1 2 1 1 PIN 2 2 PIN 1 1 FAST RECOVERY POWER AMPLIFIER THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR THE U S AND ICES 003 FOR CANADA OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION WARNING TO REDUCE THE RISK OF...

Страница 8: ...output power by 3 dB 6 dB 9 dB and 20 dB SIG is short for signal present These LEDs indicate when a signal is present after the level controls at the output stage of the power amplifier If the level controls are turned all the way down fully counterclockwise these indicators will not light 4 LEVELCONTROLS These two knobs control the levels of channels 1 and 2 The knobs are detented to make it easy...

Страница 9: ...plifier may over heat and shut down 7 SPEAKEROUTPUTS There are two options for connecting your speakers binding posts and Speakon connectors Normally you would use either the binding posts or the Speakon connectors Since the connectors are wired in parallel e g channel 1 binding post and Speakon are in parallel and channel 2 binding post and Speakon are in parallel you can connect a speaker to eac...

Страница 10: ...irtually transparent meaning you probably won t even notice any audible difference when the switch is turned on We recommend that you leave this switch on at all times However if you are working at quiet levels or you have already placed a compressor limiter in the signal path you can leave this switch off The limiter senses when the amplifier is about to be overdriven and attenuates the overall l...

Страница 11: ... If the amplifier should overheat a thermal switch turns off the power amplifier allowing the heatsink to cool down Once the amplifier has cooled to a safe operating temperature the thermal switch resets and reactivates the amplifier If this should occur identify the cause of the problem and take corrective action For example Provide better ventilation Install a fan in the rack to move more air Ma...

Страница 12: ...er serviceable See next page about service If you think your Mackie product has a problem please check out the following troubleshooting tips and do your best to confirm the problem Visit the Support section of our website www mackie com support where you will find lots of useful information such as FAQs documentation and user forums You may find the answer to the problem without having to send yo...

Страница 13: ...sure the signal cable is not routed near AC cables power transformers or other EMI inducing devices Is there a light dimmer or other SCR based device on the same AC circuit as the amplifier Use an AC line filter or plug the amplifier into a different AC circuit If possible listen to the signal source with headphones plugged into the console If it sounds noisy there the problem is not in the amplif...

Страница 14: ...tric WG Metric Wire Gauge Note that smaller AWG numbers larger 2 2 3 1 1 SHIELD COLD HOT SHIELD COLD HOT 3 SHIELD COLD HOT 3 2 1 SLEEVE TIP SLEEVE TIP RING RING TIP SLEEVE RING SLEEVE TIP TIP SLEEVE TIP SLEEVE Minimum AWG 4 ohm 8 ohm 18 10 ft 25 ft 16 25 50 14 25 75 12 50 125 10 100 200 Min Metric WG 4 ohm 8 ohm 12 3 m 8 m 14 8 15 16 8 25 20 15 40 25 30 60 COLD HOT 1 1 1 1 2 2 Use a high quality 3...

Страница 15: ...he loads For instance two 4 ohm speakers in series equals 8 ohms 4 4 8 Parallel Parallel means that the positive amp output con nects to the positive terminals of all the speakers and the negative amp output connects to the negative terminals of all the speakers If one speaker opens in a parallel configuration the others will still work but the load will change That lets you breathe a little easie...

Страница 16: ...right to change these specifications at any time without notice Mackie and the Running Man are registered trademarks of LOUD Technologies Inc All other brand names mentioned are trademarks or registered trademarks of their respective hold ers and are hereby acknowledged 2007 2008 LOUD Technologies Inc All Rights Reserved Specifications Continuous Sine Wave Average Output Power per channel both cha...

Страница 17: ...TER BRIDGE STEREO MONO BRIDGE SUBSONIC FILTER ON OFF ON OFF ON OFF ON HVDC POWER AMP 1 POWER AMP 2 PROTECTION DC OFFSET OVER TEMP SHORT CIRCUIT CURRENT LIMIT AMPLIFIER LVDC LVDC HVDC HVDC LVDC LVDC HVDC METER DISPLAY OFF CHANNEL 1 SPEAKER OUT BRIDGED SPEAKER OUT CHANNEL 2 SPEAKER OUT 1 1 2 2 1 1 2 2 TEMP SENSOR ON HEATSINK FAN VARIABLE SPEED CONTROL VDC POWER SWITCH SWITCHING POWER SUPPLY HVDC LVD...

Страница 18: ... 1700 WEIGHT 21 5 lbs 9 7 kg FRS 2800 WEIGHT 22 lbs 10 kg 19 0 in 483 mm 3 50 in 88 9 mm 1 50 in 38 mm 14 65 in 372 mm 13 46 in 342 mm 17 09 in 434 mm 14 65 in 372 mm OL 3 6 9 20 SIG OL 3 6 9 20 SIG 2 O O MAX MAX O O 1 FRS 2800 FAST RECOVERY POWER AMPLIFIER 1 50 in 38 mm Dimensions ...

Страница 19: ...nt is covered for those units deemed by us to be under warranty Note You must have a sales receipt from an authorized Mackie dealer for your unit to be considered for warranty repair IMPORTANT Make sure that the Service Request Number is plainly written on the shipping carton No receipt no warranty service E LOUD Technologies reserves the right to inspect any products that may be the subject of an...

Страница 20: ... Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail sales mackie com ...

Отзывы: