General Precautions

AC POWER REQUIREMENTS

The amplifier's power cord should be plugged into an 

AC outlet properly configured with the voltage required 
for your particular model.

Be sure the AC outlet can supply enough current to 

allow full power operation of all the amplifiers plugged 
into it. The outlet should be a three-prong socket that 
matches the power cord.

WARNING

: Bypassing the plug’s safety ground 

pin can be dangerous. Don’t do it!

The AC current demand of an amplifier varies depend-

ing on several factors, including the load impedance, 
the crest factor, and the duty cycle of the program 
material. Under typical conditions reproducing rock 
music where musical peaks are just below clipping, the 
amplifiers require the following average currents:

 

FRS•1300 = 6 A 
FRS•1700 = 8 A 
FRS•2800 =11 A

It is recommended that a stiff supply of AC power be 

used because the amplifier places high current demands 
on the AC line. The more power that is available on the 
line, the louder the amplifier will play and the more 
peak output power will be available for cleaner, punch-
ier bass.

If you have more than one amplifier sharing an AC 

outlet, you should avoid turning them all on at the 
same time. Rather, sequence them on, one at a time, 
to prevent popping the circuit breaker (due to in-rush 
current).

THERMAL CONSIDERATIONS

The power amplifier is fan cooled. Air is drawn 

through the rear panel vents, to cool down the amplifier 
heatsinks, and then expelled through the front panel 
vents.

When installing, be sure to allow sufficient air space 

around the front and rear of the amplifier for adequate 
cooling for the heatsinks. Leave at least one rack space 
above and below, and at least 6 inches behind and in 
front of the chassis to allow proper ventilation.

If the amplifier should overheat, a thermal switch 

turns off the power amplifier, allowing the heatsink 
to cool down. Once the amplifier has cooled to a safe 
operating temperature, the thermal switch resets and 
reactivates the amplifier. If this should occur, identify 
the cause of the problem and take corrective action. For 
example:

•  Provide better ventilation
•  Install a fan in the rack to move more air
•  Make sure the amplifier is not overloaded with 

too low of a load impedance or by a short circuit 
on the speaker line

RACK MOUNTING

The FRS amplifiers are designed to be mounted in a 

standard 19 inch rack. They require two rack spaces 
(2U = 3.5"). They also require 14.65" depth inside the 
rack, including the rear support brackets. When design-
ing your rack, put the heavier items at the bottom and 
the lighter items toward the top.

Secure the front panel of the amplifier to the front of 

the rack using four screws with soft washers to prevent 
scratching the panel. In addition, because of the weight 
of the amplifier, you must secure the rear support brack-
ets of the amplifier to the back of the rack. You could 
use a support rail or shelf across the back of the rack, or 
angle brackets attached between the rear support rails 
and the rear rails of the rack. This is recommended for 
all components mounted in a rack that is going to be 
moved frequently.

MAINTENANCE

Usually, your amplifier will not require regular main-

tenance for normal use. However, you can do several 
things to keep it in good operating and cosmetic condi-
tion.

•  Testing: Periodically test your system for 

proper performance. A simple test is to play a 
CD through it using well-defined, articulate, 
wide-range program material. Listen to ensure 
all drivers are working properly and for any evi-
dence of distortion or other extraneous sounds. 
Test at several volume levels: very low, normal, 
and high.

•  Cleaning: Use only a clean dry cloth to dust off 

and clean the surface. Turn off the power to the 
amplifier while you do this.

Содержание FRS

Страница 1: ...E AND THE RUNNING MAN FIGURE ARE TRADEMARKS OF LOUD TECHNOLOGIES INC CHANNEL 2 CHANNEL 1 BRIDGED BRIDGED CH 1 CH 2 CLIP LIMIT FILTER SUBSONIC 30Hz PIN 1 1 PIN 1 2 1 1 PIN 2 2 PIN 1 1 FAST RECOVERY POWER AMPLIFIER WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PER...

Страница 2: ... or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION Changes or modifications to this device not expressly approved by LOUD Technologies Inc could void the user s authority to ...

Страница 3: ...www mackie comandclickSupporttofind FAQs manuals addendums anduserforums Emailusat techmail mackie com Telephone1 800 898 3211tospeakwithoneofoursplendid technicalsupportrepresentatives MondaythroughFriday from7a m to5p m PST 22 Exposure to extremely high noise levels may cause permanent hearing loss Individuals vary considerably in susceptibility to noise induced hearing loss but nearly everyone ...

Страница 4: ...transport ing FEATURES Professional lightweight power amplifier with high power low distortion design Fast Recovery circuitry for clean undistorted sound even at clipping Ultra light switching power supply for maxi mum efficiency and minimal heat Available in three powerful models with continuous power 4 ohms bridged of FRS 1300 1300 W FRS 1700 1660 W FRS 2800 2800 W Selectable dual mono stereo or...

Страница 5: ...ables to the speaker outputs either the bind ing posts or the Speakon connectors The binding post connectors are wired as fol lows Red hot speaker terminal Black cold speaker terminal The speakon connectors are wired as follows 1 hot speaker terminal 1 cold speaker terminal 5 In bridge mode if using the binding post out puts Ch 1 red post hot speaker terminal Ch 2 red post cold speaker terminal Do...

Страница 6: ...EFER SERVICING TO QUALIFIED PERSONNEL AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR SPEAKER OUTPUTS Use only class 3 wiring FROM MIXING CONSOLE MONO OUT AMP MODE SWITCH MONO CH 1AND CH 2 PLAY THE SAME TO SPEAKERS OPTIONAL CONNECTION USING BINDING POSTS Passive loudspeakers Mackie S215 Confused cat Passive loudspeakers Mackie S215 In MONO mode both gain controls are used to acheive a nice balance OL...

Страница 7: ... FIGURE ARE TRADEMARKS OF LOUD TECHNOLOGIES INC CHANNEL 2 CHANNEL 1 BRIDGED BRIDGED CH 1 CH 2 CLIP LIMIT FILTER SUBSONIC 30Hz PIN 1 1 PIN 1 2 1 1 PIN 2 2 PIN 1 1 FAST RECOVERY POWER AMPLIFIER WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL AVIS RISQUE DE...

Страница 8: ...output power by 3 dB 6 dB 9 dB and 20 dB SIG is short for signal present These LEDs indicate when a signal is present after the level controls at the output stage of the power amplifier If the level controls are turned all the way down fully counterclockwise these indicators will not light 4 LEVELCONTROLS These two knobs control the levels of channels 1 and 2 The knobs are detented to make it easy...

Страница 9: ...s Normally you would use either the binding posts or the Speakon connectors Since the connectors are wired in parallel e g channel 1 binding post and Speakon are in parallel and channel 2 binding post and Speakon are in parallel you can connect a speaker to each con nector as long as the total impedance per channel is not less than two ohms Two 8 ohm speakers in parallel equals 4 ohms Two 4 ohm sp...

Страница 10: ... this switch on at all times However if you are working at quiet levels or you have already placed a compressor limiter in the signal path you can leave this switch off The limiter senses when the amplifier is about to be overdriven and attenuates the overall level just enough to keep the signal from clipping Clipping occurs when the output voltage no longer linearly follows the input voltage As t...

Страница 11: ... If the amplifier should overheat a thermal switch turns off the power amplifier allowing the heatsink to cool down Once the amplifier has cooled to a safe operating temperature the thermal switch resets and reactivates the amplifier If this should occur identify the cause of the problem and take corrective action For example Provide better ventilation Install a fan in the rack to move more air Ma...

Страница 12: ...er serviceable See next page about service If you think your Mackie product has a problem please check out the following troubleshooting tips and do your best to confirm the problem Visit the Support section of our website www mackie com support where you will find lots of useful information such as FAQs documentation and user forums You may find the answer to the problem without having to send yo...

Страница 13: ...sure the signal cable is not routed near AC cables power transformers or other EMI inducing devices Is there a light dimmer or other SCR based device on the same AC circuit as the amplifier Use an AC line filter or plug the amplifier into a different AC circuit If possible listen to the signal source with headphones plugged into the console If it sounds noisy there the problem is not in the amplif...

Страница 14: ... will result in higher power losses 2 2 3 1 1 SHIELD COLD HOT SHIELD COLD HOT 3 SHIELD COLD HOT 3 2 1 SLEEVE TIP SLEEVE TIP RING RING TIP SLEEVE RING SLEEVE TIP TIP SLEEVE TIP SLEEVE Minimum AWG 4 ohm 8 ohm 18 10 ft 25 ft 16 25 50 14 25 75 12 50 125 10 100 200 Min Metric WG 4 ohm 8 ohm 12 3 m 8 m 14 8 15 16 8 25 20 15 40 25 30 60 COLD HOT 1 1 1 1 2 2 Use a high quality 3 conductor shielded cable t...

Страница 15: ...t Doing load calculations with series configurations is easy just add the loads For instance two 4 ohm speakers in series equals 8 ohms 4 4 8 Parallel Parallel means that the positive amp output con nects to the positive terminals of all the speakers and the negative amp output connects to the negative terminals of all the speakers If one speaker opens in a parallel configuration the others will s...

Страница 16: ...right to change these specifications at any time without notice Mackie and the Running Man are registered trademarks of LOUD Technologies Inc All other brand names mentioned are trademarks or registered trademarks of their respective hold ers and are hereby acknowledged 2007 2008 LOUD Technologies Inc All Rights Reserved Specifications Continuous Sine Wave Average Output Power per channel both cha...

Страница 17: ...TER BRIDGE STEREO MONO BRIDGE SUBSONIC FILTER ON OFF ON OFF ON OFF ON HVDC POWER AMP 1 POWER AMP 2 PROTECTION DC OFFSET OVER TEMP SHORT CIRCUIT CURRENT LIMIT AMPLIFIER LVDC LVDC HVDC HVDC LVDC LVDC HVDC METER DISPLAY OFF CHANNEL 1 SPEAKER OUT BRIDGED SPEAKER OUT CHANNEL 2 SPEAKER OUT 1 1 2 2 1 1 2 2 TEMP SENSOR ON HEATSINK FAN VARIABLE SPEED CONTROL VDC POWER SWITCH SWITCHING POWER SUPPLY HVDC LVD...

Страница 18: ...ding to the WEEE Directive 2002 96 EC and your national law This product should be handed over to an authorized collection site for recycling waste electrical and electronic equipment EEE Improper handling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous sub stances that are generally associated with EEE At the same time y...

Страница 19: ...rn ground shipment is covered for those units deemed by us to be under warranty Note You must have a sales receipt from an authorized Mackie dealer for your unit to be considered for warranty repair IMPORTANT Make sure that the Service Request Number is plainly written on the shipping carton No receipt no warranty service E LOUD Technologies reserves the right to inspect any products that may be t...

Страница 20: ... Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail sales mackie com ...