Mackie FR Series M.2600 Скачать руководство пользователя страница 6

M•2600

oF 6 PAGES

5

O F   6   P A G E S

High-Current Power Amplifier

High-Current Power Amplifier

M•2600

AMPLIFIER

M•2600

oF 6 PAGES

6

O F   6   P A G E S

Mackie Designs Inc. continually engages in research related to product improvement. New material, 
production methods, and design refinements are introduced into existing products without notice as a 
routine expression of that philosophy. For this reason, any current Mackie Designs product may differ 
in some respect from its published description, but will always equal or exceed the original design 
specifications unless otherwise stated. ©1999-2002 Mackie Designs Inc. All rights Reserved. Mackie and 
the “Running Man” figure are registered trademarks of Mackie Designs Inc.

Part No. 091-211-00  Rev. A  6/02

www.mackie.com

16220 Wood-Red Road NE, Woodinville, WA  98072  USA

888.337.7404, fax 425.487.4337, [email protected]

UK

 +44.1268.571.212, fax +44.1268.570.809, [email protected]

ITALY

 

 +39.0522.354.111, fax +39.0522.926.208, [email protected]

FRANCE

  +33.3.85.46.91.60, fax +33.3.85.46.91.61, [email protected]

GERMANY

  +49.2572.96042.0, fax +49.2572.96042.10, [email protected]

High-Current Power Amplifier

M•2600

oF 6 PAGES

1

O F   6   P A G E S

M•2600

AMPLIFIER

Electronic files for this product available at:  

www.mackie.com

This Specification Sheet                                         M2600_SS.PDF
Owner/Operator’s Manual                                    M2600_OM.PDF
CADD files                                                                           M2600.DXF

–6 dB, –3 dB, and overload. Each channel shall have inter-
nal status LEDs appearing on the front panel to indicate 
activation of protect mode and short-circuit protection. 
Two temperature status LEDs shall appear on the front 
panel, one to indicate normal operation (COLD) and one to 
indicate thermal protection (HOT).

7. PROTECTION FEATURES.

 The amplifier shall pro-

vide delayed activation of the outputs at turn-on. Each 
channel shall have a short-circuit protection circuit for 
detecting excessive current flow at the output that, when 
activated, mutes the output for four seconds. The short-
circuit protection shall continuously cycle on and off until 
the shorted condition is remedied. The amplifier shall 
have a thermal protection circuit to protect the power 
devices from over-temperature operation. The circuit shall 
activate when the internal temperature crosses the safe-
operating threshold and, when activated, mute the out-
puts until the internal temperature cools to a safe-oper-
ating temperature, at which time amplifier shall resume 
normal operation. The amplifier shall have a fan to cool 
the heat-producing internal components, drawing cool air 
in from the front, and exhausting warm air out through 
both sides. The fan speed shall be variable, the speed 
being determined by the internal temperature and the sig-
nal level present at the output. The amplifier shall have 
an SCR crowbar circuit to protect the speakers against a 
catastrophic amplifier failure. The circuit shall activate in 
the presence of continuous DC at the speaker outputs, 
and shall shut the amplifier down by turning off the high-
voltage rails.

8. OUTPUT CONNECTIONS.

 Each channel shall have 

a heavy-duty 5-way binding post speaker output connector 
appearing on the rear panel, with 3/4" spacing for accom-
modating standard double banana plugs as well as spade 
lugs or bare wires. Each channel shall have a Neutrik 
brand Speakon

®

 output jack appearing on the rear panel 

in parallel with the binding post. A separate Speakon

®

 

connector shall be provided for the bridged mode mono 
output.

9. AMP MODES. 

The amplifier shall have a three-way 

switch appearing on the rear panel for selecting the mode 
of operation, which shall include stereo (two channels in, 
two channels out), mono (one channel in, two channels 
out), and bridge (one channel in, one channel out, bridged 
between both speaker outputs).

10. OUTPUT APPLICATIONS.

 The amplifier shall have 

a three-way switch appearing on the rear panel for select-
ing between limiter on, limiter off, and subwoofer mode. 
The defeatable electronic limiter circuit shall sense the 
onset of clipping and shall limit the input signal and there-
by prevent the output from clipping.

11. CROSSOVER.

 Each channel shall have a 4th order 

Linkwitz-Riley, 24 dB/octave crossover with switch-select-
able crossover frequencies of 60, 90, or 120Hz. When the 
subwoofer mode is selected, the two input channels shall 
be summed and the low-frequency output from the cross-
over shall be routed to the selected channel. In the full-
range modes, the high-

 

or low-frequency output of the 

crossover may be routed to the input thru connector via a 
rear panel switch.

11. LOW-CUT FILTER.

 Each channel shall have a low-

cut filter with a variable frequency control appearing on 
the rear panel covering a range of 10Hz (OFF) to 170Hz.

12. PHYSICAL CONFIGURATION.

 The amplifier shall 

be rack-mountab

l

e with rear support rails for extra sup-

port, and shall have a steel chassis frame painted gray-
black. The amplifier shall be 19" wide (483 mm), 5.2" (3U) 
tall (132mm), and 16.67" deep (423 mm), and shall weigh 
55 pounds (25 kg).

13. DESIGNATION.

 The power amplifier shall be a 

Mackie Designs M•2600.

(continued from page 5)

T

R

I

M

 

 

3

/

4

 

 

O

F

F

 

 

T

H

I

S

 

 

E

D

G

E

Содержание FR Series M.2600

Страница 1: ... 2000 watts into 4Ω Variable low cut filters on each chan nel with a range from off to 170Hz enable tighter bass response The built in limiter helps eliminate clipping Inputs are balanced unbalanced 1 4 and XLR and XLR thru outputs are switchable to send either the full range signal or the post crossover low frequency or high frequency output to another amplifier Speaker connections on the M 2600 ...

Страница 2: ...t Sensitivity 1 23 volts 4 dBu for rated power into 4 ohms Gain 32 7 dB voltage gain of 43 Maximum Input Level 9 75 volts 22 dBu Rise Time 5 µs Slew Rate Voltage Slew Rate 60V µs Current Slew Rate 30A µs at 2Ω CMRR 40 dB 20Hz to 20kHz Transient Recovery 1µs for 20dB overdrive at 1kHz High Frequency Overload and Latching No latch up to any frequency or level Variable Low Cut Filter 10Hz Off to 170H...

Страница 3: ...n constant gradi ent cooling tunnel that draws air in through the front of the amplifier and forces it through the amplifier s sides The T Tunnel design provides a shorter more direct path for cool air This allows for reduced heat build up and cooler transistor operation The amplifier has a subwoofer mode that allows you to turn on the built in subwoofer crossover When activated the signals appear...

Страница 4: ...SIG CH 1 SPEAKER OUT CH 2 SPEAKER OUT CH 1 SPEAKON CH 2 SPEAKON BRIDGED MONO SPEAKON PROTECTION CIRCUITRY MUTE DC OFFSET PROTECT SHORT OUTPUT STAGE CURRENT OUTPUT STAGE VOLTAGE TRANSIENT SOA FLT STEADY STATE SOA FLT OUTPUT DISSIPATION LOW VOLTAGE DETECT IN RUSH CONTROL CH 1 DISSIPATION MUTE LIMITER CHANNEL 2 POWER AMPLIFIER FUSE OUTPUT RELAY 100VDC 115VDC 22VAC FUSE 100VDC 15VDC 15VDC 115VDC METER...

Страница 5: ...ut signal to another amplifier or a high or low frequency crossover output for subwoofer applications Pin 2 of the XLR connec tors and the tip of the 1 4 TRS phone jack shall be non inverting 5 INPUT CHANNEL LEVEL CONTROLS Each monaural input channel shall be equipped with a gain control appearing on the front panel each having 20 detent positions and cali brated in dB and volts 6 FRONT PANEL INDI...

Страница 6: ...s drawing cool air in from the front and exhausting warm air out through both sides The fan speed shall be variable the speed being determined by the internal temperature and the sig nal level present at the output The amplifier shall have an SCR crowbar circuit to protect the speakers against a catastrophic amplifier failure The circuit shall activate in the presence of continuous DC at the speak...

Отзывы: