![Macherey-Nagel NucleoBond Xtra Midi Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/macherey-nagel/nucleobond-xtra-midi/nucleobond-xtra-midi_user-manual_3224230032.webp)
NucleoBond
®
Xtra Midi/Maxi -
English
MACHEREY-NAGEL – 01/2008/ Rev. 04
32
7.3
Concentration of NucleoBond
®
Xtra eluates with the
NucleoBond
®
Finalizers -
English
Midi - NucleoBond
®
Finalizer
Maxi - NucleoBond
®
Finalizer Large
1
Precipitate DNA
Add
0.7 volumes
of
room-temperature isopropanol
(not supplied with the
kit). Vortex well and let the mixture sit for
2 minutes
.
(e.g. for 5 ml NucleoBond
®
Xtra Midi
eluate add
3.5 ml
isopropanol, for 15 ml
NucleoBond
®
Xtra Maxi
eluate add
10.5 ml
isopropanol)
Note: The
NucleoBond
®
Finalizer
only holds up to 500 µg and the
NucleoBond
®
Finalizer Large
is limited to 2000 µg of plasmid DNA. Please check plasmid content of
your eluate prior to the precipitation step by measuring A
260
(see section 4.12). Load-
ing more DNA might lead to clogging and complete loss of your sample.
3.5 ml for
5 ml eluate
10.5 ml for
15 ml eluate
2
Load precipitate
Remove the plunger from a
30 ml Syringe
and attach a NucleoBond
®
Finalizer
to the outlet. Fill the precipitation mixture into the syringe, insert the plunger
and press the mixture slowly through the NucleoBond
®
Finalizer using constant
force. Discard the flow-through.
3
Wash precipitate
Remove the NucleoBond
®
Finalizer from the syringe, pull out the plunger and
reattach the NucleoBond
®
Finalizer to the syringe outlet.
Fill
70 % ethanol
(not supplied with the kit) into the syringe, insert the plunger
and press the ethanol slowly through the NucleoBond
®
Finalizer. Discard the
ethanol.
2 ml
5 ml