215794
87
Revision A
5.4.4
Activating Draper Speed Control Lockout
Enabling the header draper speed control lockout in the windrower
’
s cab display module (CDM) prevents unauthorized
Operators from changing the draper speed setting of the attached header.
NOTE:
•
This procedure applies to windrowers with attached draper headers only.
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
1011786
CXXX
EXXX
WINDROWER SETUP?
NO/YES
A
B
C
Figure 5.64: CDM Programming Buttons
1.
Turn the ignition key to the RUN position, or start the
engine.
2.
Press PROGRAM (A) and SELECT (C) on the CDM to enter
programming mode.
•
WINDROWER SETUP? will appear on the upper line.
•
NO/YES will appear on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? will appear on the upper line.
1011824
CXXX
EXXX
NO/YES
SET CONTROL LOCKS?
B
A
Figure 5.65: Control Locks
4.
Press SELECT (B) until SET CONTROL LOCKS? appears on the
upper line.
•
NO/YES will appear on the lower line.
5.
Press right arrow (A) to select YES. Press SELECT (B).