3.19.11
Calibrating Header Sensors
When a new header is attached to the windrower, the header
’
s sensors must be calibrated using the cab display module
(CDM) so that their output can be correctly interpreted by the windrower control module (WCM).
Calibrating Header Height Sensor
The header height sensor can be calibrated by accessing the cab display module
’
s (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensor to be correctly calibrated.
NOTE:
•
The header must be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its configuration for each header type. For more information, refer to
4.5 Attaching and Detaching Headers,
.
•
The engine must be running to perform this procedure.
DANGER
Ensure that all bystanders have cleared the area.
To calibrate the header height sensor:
1009099
CXXX
MXXX
WINDROWER SETUP?
NO/YES
A
B
Figure 3.144: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) on the CDM to enter
programming mode.
•
WINDROWER SETUP? will appear on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
•
NO/YES will appear on the lower line.
1009281
CXXX
MXXX
CALIBRATING HEIGHT
RAISE HEADER HOLD
C
B
A
Figure 3.145: Header Height Calibration
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT will appear on the upper line.
5.
Press left arrow (A) or right arrow (B) until HEADER HEIGHT
appears on the lower line. Press SELECT (C).
•
CALIBRATING HEIGHT will appear on the upper line.
•
RAISE HEADER HOLD will appear on the lower line.