3. Turn knob to scroll to REEL setting (A) on QuickMenu,
and press knob to select it. The next page opens.
Figure 4.201: Header QuickMenu
4. Turn scroll knob to highlight reel pressure ALARM (A),
and press knob to select it.
5. Turn knob to change the ALARM setpoint in
window (A). Scrolling past the highest setting turns the
alarm off. When the alarm point is off, the digital value
is replaced with three dashed lines.
6. Adjust reel alarm pressure setpoint to desired value,
and press knob to select it.
Figure 4.202: Draper Header Reel Page
4.6.6 Adjusting Draper Speed
Draper speed is displayed in mph or km/h (depending on the global units selection). The default reel speed is rpm
and can be set to auto or manual mode.
• MANUAL mode: Draper speed is manually set and is maintained independently of ground speed. Refer to
Draper Speed in Manual Mode, page 204
• AUTO mode: Draper speed is maintained relative to ground speed. Refer to
Setting Draper Speed in Auto Mode,
.
NOTE:
Both speed modes work with the One-Touch-Return feature. For example, button A on the GSL can be set for
MANUAL mode and button B can be set for AUTO mode. Refer to
One-Touch-Return Buttons (A, B, C), page 74
214053
202
Revision A
Содержание M1240
Страница 29: ...SAFETY 1 11 Safety Sign Locations Figure 1 31 Safety Sign Locations 214053 17 Revision A ...
Страница 40: ......
Страница 116: ......
Страница 246: ......
Страница 352: ...MAINTENANCE AND SERVICING Figure 5 175 Main Fuse Panel Decal MD 207815 214053 340 Revision A ...
Страница 353: ...MAINTENANCE AND SERVICING Figure 5 176 Relay Module Fuse Panel Decal MD 207816 214053 341 Revision A ...
Страница 355: ...MAINTENANCE AND SERVICING Figure 5 178 Roof Headliner Fuse Decal MD 207819 214053 343 Revision A ...
Страница 370: ......
Страница 388: ......
Страница 487: ......