214325
192
Revision A
Figure 5.113: Header Control Cluster
4.
Use HEADER HEIGHT SETPOINT control dial (A) as
necessary to fine-tune setpoint position.
Header In-Field Settings
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Figure 5.114: Header Groups
1.
To quickly view header group settings, touch HEADER
icon (A) that is second from bottom on right of Tyton
terminal home page.
2.
The display area shows:
•
(B)
–
The left header height indicator is current
position of header.
•
(C)
–
The red line on current header height position
indicator (B) shows setpoint cut-off position.
•
(D)
–
Adjust setpoint cut-off position by touching
HEADER symbol and using scroll wheel on right of
Tyton terminal. As scroll wheel is moved, position of
cut-off will move.
•
(E)
–
The right indicator is set cut height for AHHC.
Fine-tune cutting height with header height setpoint
control dial on header control cluster. As control is
adjusted, cut height indicator will move.
•
(F)
–
The header working width.
•
(G)
–
Header pitch.
3.
Touching a field opens on-screen keyboard so that
values can be adjusted. Enter new value and touch
green check mark when complete.