214325
177
Revision A
When SENSITIVITY ADJUSTMENT dial (A) is set to maximum (turned completely clockwise), only small changes
in ground height are needed to cause feeder house to raise or lower. In this position, cutterbar moves up and down
approximately 19 mm (3/4 in.) before control module signals hydraulic control valve to raise or lower header frame.
When SENSITIVITY ADJUSTMENT dial (A) is set to minimum (turned completely counterclockwise), large
changes in ground height are needed to cause feeder house to raise or lower. In this position, cutterbar moves up
and down approximately 51 mm (2 in.) before control module signals hydraulic control valve to raise or lower
header frame.
The HEADER SENSE LINE input also changes range of sensitivity. When connected to a draper, counterclockwise
position (least sensitive) allows for approximately 102 mm (4 in.) of vertical travel before correction is made.
Troubleshooting Alarms and Diagnostic Faults (Gleaner R65/R66/R75/R76 and S Series)
NOTE:
Refer to
5.1.7 Gleaner S9 Series Combines, page 179
for information specific to Gleaner S9 Series.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Figure 5.81: Tachometer
Display type:
Displayed on tachometer (A) as XX or XXX.
Displayed on LCD (A) as XXX cm or XX in.
Содержание FFT FD75
Страница 2: ...FD75 FlexDraper Combine Header Published June 2017...
Страница 10: ......
Страница 24: ......
Страница 148: ......
Страница 188: ...214325 178 Revision A Figure 5 82 Combine Heads Up Display SETTING UP AUTO HEADER HEIGHT CONTROL...
Страница 282: ......
Страница 288: ......
Страница 304: ......
Страница 307: ......