MAC TOOLS Mentor Touch ET750 Скачать руководство пользователя страница 10

1 689 989 285

2020-02-24

Robert Bosch GmbH

 

!

You will find the "END-USER LICENSE AGREEMENT 
(EULA) FOR MICROSOFT SOFTWARE" (EULA.XPS) 
on the Desktop. Please observe the notes contained 
herein.

4.4 

Description of device

The ET750 is a portable, mobile tablet PC for workshop 
use. It is operated by means of a pen (for the LCD 
touch screen) and a virtual keypad. The data and 
measured values can be printed out by way of the USB 
interface on an external printer (special accessory). The 
ET750 and the accessories are supplied in a protective 
case.

1

3

4

5

459966-02_Re

2

Fig. 1: 

ET750

1  LCD with touch screen
2 Interfaces
3 Stylus
4  Function key �
5  On/Off button

4.4.1 

Interfaces

459966-04_Re

1

2

3 4 5 6

Fig. 2: 

View of ET750 interfaces

1  RJ-45 network connection (LAN) 
2  Monitor connection
3  USB port (2x), USB 3.0, max. 1 A
4  Memory card slot (SD card)
5  Headphone connection
6  Power supply unit connection (12 V DC)

10  |  ET750  |  Product description

en

4.  Product description

4.1 

Intended use

The ET750 is a diagnostic system for workshops and 
with diagnostic device ET650 

solely

 intended to be used 

for the control unit diagnosis with the "HUB" software. 
The operating system Windows 10 IoT 64-bit) and the 
"HUB" software has been installed on the ET750.

HUB can execute the following functions:

 

R

Control unit diagnosis

, with e.g.

 

$

read DTCs 

 

$

display actual values

 

$

activate actuators 

 

$

use other specific control unit functions

 

!

ET750 may only be operated with the storage battery 
of Robert Bosch GmbH (Model: 2ICR18/65-2) and 
the power supply unit of Elementech International 
Co. LTD. (Model No.: A160-1120500M).

 

!

The installation of additional software on the ET750 
may impair the performance of the ET750 system 
and the ET750 may become slower in general. This 
applies in particular to virus scanner programs. 

 

!

The ET750 is a precision device which is not to be 
subjected to sources of heat (e.g. direct sunlight), 
impact, vibration, magnetic fields and excessive 
soiling.

4.2 

Scope of delivery

 

i

The scope of delivery depends on the product 
variant ordered as well as the special accessories 
ordered, and can deviate from the following list.

Designation

Order number

ET750

ET650

Storage battery 

1 687 335 053

USB connecting cable (1.8 m)

1 684 465 507

OBD connection cable (1.5 m)

1 684 465 555

Connection cable for  

cigarette lighter socket

<)

1 684 465 784

Case

Power supply unit

1)

 with

power supply cable and 

power supply cable (en)

1 687 023 697

1 684 461 186

S P03 100 647

SD memory card (SW-Recovery)

Original operating manuals

1)

  The power supply unit included in the scope of delivery can be 

used for the voltage supply of both the ET750 and the ET650. 

4.3 

Transportation

The ET750 connecting cables must be removed for 
transportation purposes. In addition, the ET750 and 
ET650 should only to be transported and stored in the 
supplied case. 

Содержание Mentor Touch ET750

Страница 1: ...ET750 en Operating instructions Diagnostic System ET750 ET650...

Страница 2: ......

Страница 3: ...l unit diagnosis 13 4 6 2 Firmware update 13 5 Initial commissioning 13 5 1 Fitting the storage battery 13 5 2 Connection 13 6 Operation ET750 14 6 1 Switching on the ET750 14 6 2 Switching off the ET...

Страница 4: ...ices also indicate the consequences of the hazard as well as preventive action Warning notices have the following structure Warning symbol KEY WORD Nature and source of hazard Consequences of hazard i...

Страница 5: ...ational agreements and other national legal regulations Copying or selling of data and software or any part thereof is impermissible and punishable in the event of any infringements Bosch reserves the...

Страница 6: ...uipment and operating material is operated in keeping with electrical engineering principles If a piece of electrical equipment or operating material is found to be defective i e it does not or no lon...

Страница 7: ...es Make sure that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ignition Never open the enclosures 3 1 2 H...

Страница 8: ...ries and rechargeable batteries avoid getting it on your skin or in your eyes Rules of conduct If contact with skin or eyes happens nevertheless wash the affected parts immediately with clean water an...

Страница 9: ...lways ensure effective ventilation and suction when working in closed areas 3 6 Danger of asphyxiation Car exhaust fumes contain carbon monoxide CO a colorless odorless gas If inhaled carbon monoxide...

Страница 10: ...e g read DTCs display actual values activate actuators use other specific control unit functions ET750 may only be operated with the storage battery of Robert Bosch GmbH Model 2ICR18 65 2 and the powe...

Страница 11: ...and switches off the ET750 i i Pressing the On Off button for 5 seconds switches off the ET750 without first shutting down the operating system This mode should only be used if shutdown of the Windows...

Страница 12: ...ot present Check power supply Flashes green 1 second interval ET650 ready for operation None Illuminated green Fault in hardware Firmware Flashes yellow 1 second interval Overvoltage on diagnostic cab...

Страница 13: ...upply the ET650 using the provided power supply unit and connect to ET750 using the USB connecting cable Do not interrupt the USB connection during the firmware update The firmware update can also be...

Страница 14: ...r options The menu Start Control panel Power options can be used to select and alter the power plan e g the monitor switch off time or the display brightness setting 5 3 Configuration of the operating...

Страница 15: ...The ET750 features a virtual keypad Pressing the icon in the task bar or pressing the function key for 2 seconds opens or closes the on screen keyboard as applicable The on screen keyboard functions...

Страница 16: ...ng a HUB update installation always supply the ET750 with voltage by way of the power supply unit The further update installation procedure is described in detail in the HUB online help 6 13 Informati...

Страница 17: ...gain This switch off procedure is only to be employed if the ET750 will not react to any key being pressed as it may result in loss of data on the hard disk if it is implemented during regular operati...

Страница 18: ...tery charge indicator can be called up via the icon The storage battery charge indicator shows the current battery charge on a scale of 0 to 100 i i It is advisable to charge the battery for at least...

Страница 19: ...1 684 461 186 Power supply cable en S P03 100 647 Stylus 3 pc 1 687 010 403 SD memory card SW Recovery Windows 10 Enterprise 2016 LTSB 1 688 400 635 SD memory card SW Recovery Windows 10 Enterprise 2...

Страница 20: ...rd disk 256 GB SSD WLAN WLAN 802 11 b g n Bluetooth Bluetooth 2 1 Class 1 Storage battery Li ion 7 26 V 5200 mAh Dimensions H x W x D 249 x 329 x 53 mm 9 8 x 12 9 x 2 1 inch Weight with storage batter...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...Robert Bosch GmbH Automotive Service Solutions Franz Oechsle Stra e 4 73207 Plochingen DEUTSCHLAND www bosch com bosch prueftechnik bosch com 1 689 989 285 2020 02 24...

Отзывы: