![Mac Medical S0050 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/mac-medical/s0050/s0050_instruction-manual_685277010.webp)
Instruction Manual
MAN-028
10
www.macmedical.com
Service
Compatible liquids
Wetted materials
Housing: brass; Piston: polysulfone; Spring: 316SS; O-Ring: Fluoroelastomer,
Other: Epoxy
Temperature Limits
-20 to 225°F (-29 to 107°C)
Pressure Limits
1000 psig (68.9 bar)
Accuracy
±10% of set point
Repeatability
±1%
Switch Type*
SPDT, 20 VA
Electrical Rating
.17 A @ 120 VAC, .08 A @ 240 VAC, .13 A @ 120 VDC, .06 A @ 240 VDC
Electrical Connection
18 AWG, 24" (60.96 cm), Polymeric lead wires
Process Connection
1/4" female NPT
Mounting Orientation
Any position. Set points shown are based on vertical, inlet down position.
Required Filtration
50 microns or better
Weight
0.66 lb (301 g)
Agency Approval
CE
InLine Flow Switch Timer Controller (S0130-01)
Specifications, Switch Rating and Wiring Diagram
This is an explosion-proof brass flow switch, actuation set point 0.50 GPM (1.89 LPM), and
calibrated for water at standard conditions. It is used for accurate detection of excessive or
insufficient flow rates.
*Switch Ratings
Max Resistive Load
This unit was calibrated in a vertical position, with lead wires up. Install unit in piping system,
using standard pipe fitting procedures. Be sure to keep thread sealing compound out of
unit. Make sure that flow is in proper direction - marked
“IN”
and
“OUT”
on housing. See
wiring diagrams for electrical connections.
CAUTION:
See “Switch Ratings” before connecting power.
CAUTION:
Flow settings for this switch is normally calibrated using water at +70°F on
increasing flow. Water-calibrated units are not recommended for air/gas applications.
VA
Volts
Amps
AC
Amps
DC
20
0-30
.4
.3
120
.17
.13
240
.08
.06
A
C
B
Pin Connections for
Units with MS Receptacle