FUNCTION TEST SEQUENCE (cont.)
6 Turns
Drive motor runs; heat source is on.
DRYING
LED is lit. Control thermistor reading is displayed. **
To exit test mode, press and hold the
SELECT
and
PAUSE CANCEL
buttons
simultaneously for six seconds or disconnect power from dryer. Dryer will be reset for
regular operation.
**
The dryness LEDs are used to determine the control thermistor reading. The number of
flashes of the bottom three LEDs will determine the value of the temperature as follows:
NORMAL =
HUNDRED’S
LESS DRY =
TEN’S
DAMP =
ONE’S
Example: NORMAL
flashes 1 time.
LESS DRY
flashes 2 times.
DAMP
flashes 6 times.
Temperature = 126 degrees.
mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. January 2007