76
319,5
113,5
Outdoor unit floor fixing dimensions.
Units in mm
583
113,5
For 24 000 BTU/h systems
317
130
Outdoor unit floor fixing dimensions.
Units in mm
500
150
For 24 000 BTU/h systems
256
140
Outdoor unit floor fixing dimensions.
Units in mm
500
140
For 9 000 BTU/h, 12 000 BTU/h
and 18 000 BTU/h systems
selection of pipes
Liquid pipe
(diameter)
Gas pipe
(diameter)
9000 and some
12000 BTU
systems
24000 BTU
systems
6,35 mm (1/4")
6,35 mm (1/4")
9,52 mm (3/8")
15,9 mm (5/8")
NOTE:
The thickness of the pipe must be 0,8 mm at least.
18000 and
some 12000
BTU systems
6,35 mm (1/4")
12,7 mm (1/2")
In order to know the pipe diameter of the acquired model, check
the model label located on one side of the unit.