MAINTENANCE/CLEANING

 

For best performance, clean your unit every 6 to 12 months, 

depending on the level of contaminates in your home or office.

BEFORE ANY MAINTENANCE OR CLEANING ALWAYS POWER 

OFF AND UNPLUG THE UNIT!

 

Exterior Cleaning 

If needed, wipe down the unit with a damp cloth and dry with a soft 

cloth. 

 

Cleaning the Filter Assembly 

Make sure you clean each membrane of the filter separately 

(honeycomb, foam and mesh) with compressed air or water. Let dry 

and place them back into the filter in this order: Honeycomb, foam 

and mesh. Lastly, attach the rim onto the filter.

Ionization Needles 

Gently clean the ionization needles with a Q-tip soaked in rubbing 

alcohol. 

 

Purification Plate 

Soak the Purification Plate in a 50/50 mix of warm water and clear 

ammonia or use a 50/50 mix of water and rubbing alcohol. Leave the 

plate in the solution mix for 2 hours. Next, gently scrub the 

Purification Plate’s mesh with a soft bristled brush until you no longer 

see any debris. Rinse off, air dry and use a soft cloth to clean the 

Purification Plate contacts. Re-install Purification Plate into the unit.

Cleaning the Interior 

Gently clean the interior with a vacuum, a damp cloth, compressed 

air etc. after the unit has been disassembled. 

 

Changing the Fuse 

The fuse is located next to the switch on the backside of the unit. Use 

a small flathead screwdriver and gently remove the fuse. One extra 

fuse is included. 110 volt models: Use 3.5 amp slow blow fuse. 

 

Содержание Medi

Страница 1: ...Medi Air Purifier MA International Trading Co Inc DBA Medi Air Purifier www mediairpurifier com Phone 800 953 7228 mediairpurifier gmail com...

Страница 2: ...purifier excluding the plate and rear filter assembly which require replacement due to normal use Though the APCO cell is an exchangeable part the cell is still covered under warranty for a period of...

Страница 3: ...ers Power Cord Input 110 VAC 60 Hz Output 110 VDC 50W See the power supply label for certifications and warnings APCO Cell Normal Mode Output 0 02 ppm ozone ambient room concentration Purification Pla...

Страница 4: ...fier you can rest assured that both the air you re breathing and the surfaces you re touching are safe and pollution free Ease of Use The Medi Air Purifier utilizes complex and advanced technology to...

Страница 5: ...he Medi Air Purifier you have the flexibility of creating a safe healthy environment in both the largest and smallest of spaces Needlepoint Ionization The Medi Air Purifier utilizes needlepoint ioniza...

Страница 6: ...DIAGRAMS 1 Ionization Needles 2 Front Grille 3 Control Panel 1 Front Grille 2 Rear Cover 1 Rear Cover Clasp 2 Rear Cover Screw 3 Power Cord Insert 4 Fuse...

Страница 7: ...DIAGRAMS 1 Thumbscrew 2 Filter Assembly 3 Filter Assembly Clasp 1 APCO Cell 2 APCO Cell Nut 3 Purification Plate 4 APCO Cell Connector...

Страница 8: ...DIAGRAMS 1 Power Button 2 Fan Speed Control 3 Purifier Level Control 4 Normal High Mode Control 5 Away Mode Control...

Страница 9: ...DIAGRAMS 1 Fan Speed Indicator 2 Purification Level Indicator 3 Away Mode Indicator 4 Away Mode Warning 5 Maintenance Reminder 6 Ion Indicator 7 Purification Level Warning...

Страница 10: ...DIAGRAMS Normal Mode High Mode Away Mode...

Страница 11: ...DIAGRAMS Remote Control...

Страница 12: ...ance away from HVAC vents Ensure there is plenty of room in front of the unit for purification so that it can operate at maximum capacity Starting the Unit Before turning on the unit first determine t...

Страница 13: ...When in Normal Mode press the Normal High Mode The High Mode will then show on the LCD screen Once on High Mode you can then adjust the square footage settings by pressing the Purifier Up Purifier Do...

Страница 14: ...amic plate needs to be cleaned for the unit to run at peak performance To clean the ceramic plate follow the instructions laid out in this manual After cleaning the ceramic plate press the Away Mode b...

Страница 15: ...e the unit with a broken plate Do not stare directly into the lamplight inside the unit Do not set the unit to cleanse an area larger than the square footage of your home or office Never use the Away...

Страница 16: ...Gently pull the top of the Filter Assembly free of the unit Unlock the tabs on the Filter to expose the mesh foam and honeycomb membranes of the Filter Disassembling the Purification Plate Instructio...

Страница 17: ...semble the purification plate carefully slide it back into the Purification Plate slot Be very gentle when re installing the plate Do not force it into the slot as this could cause serious harm to you...

Страница 18: ...edles with a Q tip soaked in rubbing alcohol Purification Plate Soak the Purification Plate in a 50 50 mix of warm water and clear ammonia or use a 50 50 mix of water and rubbing alcohol Leave the pla...

Страница 19: ...al turn off the lights in the room Also turn off the APCO light with your remote control and look for a purple or blue light glowing within the unit The APCO Cell is not Giving Off a Light Check to ma...

Страница 20: ...Medi Air Purifier...

Отзывы: