MA lighting MA 2Port Node Скачать руководство пользователя страница 37

 

  MA 2Port Node 

 

 

Data 

 

Transport 

 

Safety 

instructions 

 

Safety and 

environment 

 

Quickstart  

Connect 

 

Quickstart  

ON / OFF 

 

Maintenance 

 

Conformity 

 

 

36 

Update without session 
 
Hinweis.  

Do not use so-called Type U3 USB-sticks (with two physically drives on a single USB-stick) for 
firmware-update. 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 



create an USB-stick with  STICKMAKER 

 programm and installation programm 4port_v1.x.y.imgz. (free of 

charge download from MA-web site)  

connect  USB-stick. 

switch on MA 2Port, short afterthere following instruction appears: 

 

Please press key for update/recovery

 

 

 

 press button  MENU now. 

Now following instruction appears 
 

Please press key for FORMAT

”.

 

Simultaneously for an few seconds a loading bar starts. 

- When the button MENU is pressed within this few seconds, the MA 2Port Node will be reseted. And 

after automatc reboot the IP address is set to 192.168.0.xxx (xxx means the last three digits of serial 
number of the unit) 

- When the button MENU is not pressed within this few seconds, the MA 2Port Node will be updated  

 all 

settings remain. 

After instruction 

Please remove USB stick for reboot

” 

please remove the stick, MA 2Port Node starts booting 

automatically. 

 

Содержание MA 2Port Node

Страница 1: ...MA 2Port Node QuickMAnual Version XIX 6 deutsch english Art Nr 1366M 00163...

Страница 2: ......

Страница 3: ...ht ein 2 TFT Display und vier Status LEDs Zus tzlich befindet sich ein USB Port f r einen optionalen Firmware Update per USB Stick Auf der Ger ter ckseite sind der Hauptschalter ein powerCON und ether...

Страница 4: ...re betrieben werden Hersteller MA Lighting Technology GmbH Dachdeckerstra e 16 D 97297 Waldb ttelbrunn Mehr Informationen und detaillierte Manuals f r die onPC Software unter www malighting com Oft ge...

Страница 5: ...3 x 1 8 x 7 3 inch 2 DMX OUT XLR 5 pin an der R ckseite Die DMX OUTs k nnen auch zu DMX IN konfiguriert werden Ethernet RJ 45 Netzwerk Anschluss USB Anschluss an der Front nur f r Updates per USB Stic...

Страница 6: ...ierte und gesch tzte Kabel verwenden min 3 x 1 0mm Kabel und Stecker sind nicht im Lieferumfang enthalten Erforderlicher Steckertyp Power In PowerCon blau von Fa NEUTRIK AG Liechtenstein Erforderliche...

Страница 7: ...usschlie lich der Anwender verantwortlich bei Nichtbeachten k nnen Personen oder Sachsch den entstehen Verwenden Sie f r Lagerung und Transport eine sichernde und sch tzende Transportvorrichtung Stell...

Страница 8: ...Quickstart ON OFF Wartung Konformit t 07 Symbole und Warnzeichen I 0 Achtung Warnung vor einer Gefahrenstelle Achtung Warnung vor Gef hrlicher elektrischer Spannung Hauptschalter AN AUS Wechsel strom...

Страница 9: ...uss Stellen Sie keine Gegenst nde auf das Netzkabel und achten Sie darauf dass niemand auf das Kabel treten kann Wird ein Verl ngerungskabel benutzt muss sichergestellt werden dass die Summe der Nennl...

Страница 10: ...Wartung Konformit t 09 Warnhinweise Die Wartung des Ger tes darf ausschlie lich durch geschultes Personal durchgef hrt werden da beim ffnen und oder Entfernen von Abdeckungen spannungsf hrender Teile...

Страница 11: ...F bis 122 F Luftfeuchte Betrieb 20 bis 90 relative Luftfeuchtigkeit keine Betauung Lagerung Transport 10 bis 90 relative Luftfeuchtigkeit keine Betauung Umgebung Bitte alle Sicherheitshinweise beachte...

Страница 12: ...nada Das Netzteil passt sich automatisch an die Netzspannung an Hauptschalter Zum Ein Ausschalten des Ger tes USB Anschluss zum Updaten per USB stick keine Peripherieger te anschlie en MENU Taster zum...

Страница 13: ...nPC command wing und MA onPC fader wing addieren in beliebiger Kombination Parameter bis zur maximalen Parameterzahl Rechenbeispiel 1 grandMA2 onPC MA onPC command wing 2 048 Parameter MA 2Port Node o...

Страница 14: ...2Port DMX Output z B 30 Frequenz des DMX Ausgangs in Hz max 30Hz sind m glich IP Adresse z B 192 168 0 244 Mode MANET2 oder ARTNET Nummer der Session z B Session 1 der MA 2PORT Node befindet sich in d...

Страница 15: ...ige wieder auf das erste Men zur ck Select Mode Mit dem MENU Button NONE MANET 2 oder ARTNET einstellen Info Mode hier k nnen keine Einstellungen vorgenommen werden Identify Mode Markiert in der Konso...

Страница 16: ...ch erscheint die Anweisung Please press key for update recovery Jetzt die Men Taste dr cken Jetzt erscheint die Anweisung Please press key for FORMAT Gleichzeitig startet f r ein paar Sekunden ein Lau...

Страница 17: ...n MA 2Port Node in der bersicht selektieren Den Button SOFTWARE UPDATE dr cken Nach dem automatischen Reboot des MA 2Port Node muss das Feld Version grau unterlegt sein HINWEIS wenn im Display der Hin...

Страница 18: ...In der Konsole oder onPC das Men SETUP NET WORK MASTER MA NETWORK CONFIGURATION DMX NODE ffnen Bei Bedarf die Firmware Version des MA 2Port Node angleichen falls das Feld Version rot unterlegt ist IP...

Страница 19: ...espeichert sie muss mit SAVE TO DEFAULT gesondert gespeichert werden Laden der Konfiguration Im Men SETUP NETWORK MA NETWORK CONFIGURATION DMX NODES den Button LOAD FROM DEFAULT dr cken Falls nach dem...

Страница 20: ...scharfe Reiniger verwenden Darauf achten dass die ffnungen f r die K hlluft frei sind Je nach Umgebungsbedingung ist es ratsam das Ger t alle 2 5 Jahre durch einen autorisierten Service reinigen zu l...

Страница 21: ...oduktkategorie Kontrollger t Produktnamen MA 2Port Node MA 2Port Node onPC 1k MA 2Port Node onPC 2k den folgenden Richtlinien sowie den harmonisierten Normen entsprechen Sicherheit EN60065 EN60950 1 L...

Страница 22: ...ren am Laptop oder PC Mit der grandMA 3D Software kann es zum perfekten Designstudio erg nzt werden und es ist die Grundlage f r die Funktion des MA 2Port Node onPC Die grandMA2 onPC und grandMA 3D So...

Страница 23: ...en in der Licht Szene ger stet Au erdem bietet das neu entwickelte faderwing bis zu 60 zus tzliche Executor Fader Und die grandMA2 full size kann die showfiles der Serie 1 in einem speziellen Serie1 M...

Страница 24: ...ere is a USB port for optionally update of firmware via USB stick The mains switch is located on the back along with the powerCON and etherCON connectors as well as two DMX ports The MA 2Port Node is...

Страница 25: ...mbH Dachdeckerstra e 16 Germany D 97297 Waldb ttelbrunn For more information and detailed manuals see www malighting com Please check our Frequently Asked Questions first that you can find online at w...

Страница 26: ...85mm 8 3 x 1 8 x 7 3 inch 2 DMX OUT XLR 5 pin on the rear side Each DMX OUT can be individually configured as DMX IN Ethernet RJ 45 network connector USB Port connector on the front side For update vi...

Страница 27: ...ng necessary Power cable Only adequately protected cables may be used min 3 x 1 0mm Power supply cabel and connector not included ex works Socket type Power In PowerCon blue by NEUTRIK AG Liechtenstei...

Страница 28: ...and for observing the safety regulations of the manufacturer when using means of transport Non compliance can result in personal injury or material damage Use protective transport device for transport...

Страница 29: ...ment Quickstart Connect Quickstart ON OFF Maintenance Conformity 28 Symbols and warning labels I 0 Warning Danger Area Warning Danger of electric shock Supply voltage ON OFF Alternating current AC Dis...

Страница 30: ...s provided with a safety plug This plug can only be used with safety sockets These precautions should by all means be followed If the plug should not fit into a given socket e g the case with old sock...

Страница 31: ...kstart Connect Quickstart ON OFF Maintenance Conformity 30 Electric shock warning The unit should be serviced by qualified personnel only as live parts may be exposed when opening and or removing cove...

Страница 32: ...nsport 10 C up to 50 C 14 F up to 122 F Humidity Operation 20 up to 90 relative humidity no condensation Storage Transport 10 up to 90 relative humidity no condensation Environment Follow all the IMPO...

Страница 33: ...matic operation no switching necessary The open end must be fitted with a shock proof plug and must meet the local requirements Main switch To turn on or off the device USB socket To update via USB st...

Страница 34: ...le The maximum parameter count with grandMA2 onPC is 4 096 parameters Second rule In any combination MA 8Port Nodes onPC MA 4Port Node onPC MA 2Port Node onPC as well as MA onPC command wing and MA on...

Страница 35: ...l show this menu Name of MA 2Port Node e g 2Port DMX Output e g 30 frequency of DMX output in Hz max 30Hz possible IP Address e g 192 168 0 244 Mode MANET2 or ARTNET Number of Session e g Session 1 MA...

Страница 36: ...After a short time display returns to the above menu Select Mode Use the MENU button to select NONE MANET 2 or ARTNET Info Mode no settings possible Identify Mode identifies this MA 2Port Node by flas...

Страница 37: ...e following instruction appears Please press key for update recovery press button MENU now Now following instruction appears Please press key for FORMAT Simultaneously for an few seconds a loading bar...

Страница 38: ...32 with installation program 4port_v1 x y update Open menu SETUP NETWORK MA NETWORK CONFIGURATION DMX Nodes at the console or onPC Connect USB stick with the console Select the appropriate MA 2Port No...

Страница 39: ...l only show the most important settings For configuring a node you have to use a grandMA console or the onPC software Console or onPC open menu SETUP NET WORK MASTER MA NETWORK CONFIGURATION DMX NODE...

Страница 40: ...d SAVE SHOW settings of the MA 2Port Node are not stored settings must be stored with SAVE TO DEFAULT Load Configuration settings Open menu SETUP NETWORK MA NETWORK CONFIGURATION DMX NODES and press b...

Страница 41: ...surface only with dry soft cloth Do not use any liquid cleaner or compressed air Do not use any solvent Check ventilation holes are clear Depending on the environment we recommend to clean the device...

Страница 42: ...ategory Control unit Name of products MA 2Port Node MA 2Port Node onPC 1k MA 2Port Node onPC 2k complies with the following product specifications and harmonized standards Safety EN60065 EN60950 1 LVD...

Страница 43: ...used for running programming or offline programming a show Furthermore it is expandable to a complete design studio by connecting it to grandMA 3D and it s the basis for the function of the MA 2Port...

Страница 44: ...ghting segments Intuitive and fast control over all connected fixtures and channels in different styles is self evident Furthermore the newly developed faderwing provides in addition up to 60 executor...

Страница 45: ...44 Ger tetyp model MA 2Port Node MA 2Port Node onPC 1k MA 2Port Node onPC 2k Optionen options Seriennummer serial number Baujahr year of manufacture Distributor...

Страница 46: ...45 Notizen notes...

Страница 47: ...ormation contained in this booklet were correct at time of printing By continuing our company s efforts to optimize our products continuously it may happen that information is outdated at the time you...

Отзывы: