M2TECH PALMER POWER STATION Скачать руководство пользователя страница 9

PALMER POWER STATION

 

LOW NOISE BATTERY POWER SUPPLY/CHARGER 

REVISION P

r

A – NOVEMBER 2011 

 

Copyright © 2011, M2Tech Srl 

9

 

M2Tech 

www.m2tech.biz 

 

5. Operation 

 

5.1. Charge policy 

 
Charge is activated whenever one of the following events occur: 
 
a) the unit is powered, the battery is in use and the battery voltage falls below the low 
battery limit; 
b) the unit is off (mains switch released, Page 6 no.1), the output switch is on and the unit 
is powered by pushing the mains switch. 
 
When the unit gets powered with the outputs enabled, chances are that the battery has 
been used down to the full capacity, so a charge cycle needs to be started. User may use 
this to start a charge at any time by just powering the unit with the outputs enabled. 
 
On the other hand, powering the unit with the outputs disabled puts the unit in a “charge 
idle” status in which a charge is only activated when the battery is depleted. 
 

5.2. Forced battery operation 

 
As stated in paragraph 5.1., the 

PALMER POWER STATION

 initiates a charge cycle every time 

the battery voltage reaches the low battery level while the unit is powered. When the 
charge is in progress, the low-noise post-regulator is fed by a pre-regulator to ensure 
uninterrupted operation of the unit(s) connected to the 

PALMER POWER STATION

 output(s). 

 
User may prefer not to have the charge started before ending the listening session, thus 
using all the safe battery capacity. This is achieved by simply switching the 

PALMER POWER 

STATION

 off. The battery will feed the post-regulator even when its voltage falls below the 

low battery threshold, down to a safety depletion level. When this depletion level is 
reached, a protection circuit will disable the output, totally isolating the battery and 
avoiding any further depletion which may damage it. 
 

5.3. Battery safety and life duration 

 
The Li-Po battery used inside the 

PALMER POWER STATION

 is a very high quality unit, with 

long life and high surge current. To avoid damaging it, protections are included in the 

PALMER POWER STATION

 circuit, as well as inside the battery itself. 

 
The battery is protected against: 
 
a) undervoltage (depletion); 
b) overvoltage due to charge circuit faults; 
c) overcurrent, by both the internal circuit and a resettable polyswitch fuse. 
 

Содержание PALMER POWER STATION

Страница 1: ...M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY CHARGER USER MANUAL REV PRA 10 2011 ...

Страница 2: ...his unit is compliant with the following CE regulations CEI EN 55022 2009 Class B Radiated Emissions CEI EN 55024 1999 CEI EN 55024 A2 2003 CEI EN 55024 IS1 2008 Radio Frequency Electromagnetic Fields 50Hz Magnetic Field Immunity Test and Electrostatic Discharges ESD Recycling The label above printed on the product case indicates that the product when no more usable can t be treated as generic gar...

Страница 3: ...tor while the battery is being charged This allows for uninterrupted operation and certain full charge time PALMER POWER STATION has two outputs to power two M2Tech 15V devices like the YOUNG 384 32 DAC and the JOPLIN 384 24 ADC They can be switched off when the powered devices are not used to save battery charge A universal mains input internal supply allows for operation all over the world witho...

Страница 4: ...EMBER 2011 Copyright 2011 M2Tech Srl 4 M2Tech www m2tech biz INDEX 1 Unpacking 5 2 Front Panel 6 3 Back Panel 7 4 Connections 8 5 Operation 9 5 1 Charge policy 9 5 2 Forced battery operation 9 5 3 Battery safety and life duration 9 5 4 Placement 10 6 Technical Specifications 11 ...

Страница 5: ...g The PALMER POWER STATION box contains the following items Palmer Power Station 1 supply cable terminated with 5 5 2 1mm plug on one end and with Bulgin heavy duty plug on the other end 1 power cord Should any item be missing please contact your dealer for a warranty claim Please note the supply cable may be obtained as a separate item if needed ...

Страница 6: ...rminated at any time by switching power off Please see Section 5 for the effect of this switch status over battery charge start policy 2 Output switch Enables and disables both outputs It s useful to switch powered units off by this switch when not listening to music to save battery charge and avoid undesired charge cycles thus increasing battery life Please see Section 5 for the effect of this sw...

Страница 7: ...0 60H AC Z WARNING NO USER SERVICEABLE PARTS INSIDE REFER ALL SERVICING TO QUALIFIED PERSONNEL OUT 1 OUT 2 MADE IN ITALY S N POWER CONSUMPTION 60VA FUSE 2 x 2 5A Slow BLOW 5 5 6 7 5 Outputs Connect the supply cable provided in the package Positive is the upper hole negative is the lower hole 6 Charge indicator Fuses holder Contains two 2 5A slow blow 5x20mm fuses 7 Mains socket Connect the power c...

Страница 8: ...he mains socket Page 7 no 7 of PALMER POWER STATION Connect the Bulgin plug of the supply cable to one of the PALMER POWER STATION output connectors Page 7 no 5 Connect the 5 5 2 1mm plug of the supply cable to a 15V operated M2Tech device Of course two cables may be used when two devices need supply otherwise the other output will be unused Connect the plug of the power cord to a wall outlet ...

Страница 9: ...the battery voltage reaches the low battery level while the unit is powered When the charge is in progress the low noise post regulator is fed by a pre regulator to ensure uninterrupted operation of the unit s connected to the PALMER POWER STATION output s User may prefer not to have the charge started before ending the listening session thus using all the safe battery capacity This is achieved by...

Страница 10: ... not short circuit the outputs Should the PALMER POWER STATION be exposed to temperature beyond the allowed range put the unit in a normal environment and allow for at least one hour before operating it Too cold or too hot a battery would result in damage when operated Please refer to the specifications section Page 11 for temperature limits Moreover it s advisable not to overcharge nor short circ...

Страница 11: ...ltage 15VDC battery Output current 1A peak both outputs Output noise 15µVrms 20 20 000Hz bandwidth Output regulation TBD 0 to 500mA output current Battery duration min 14 hours 240mA output current Battery charge time 3 5 hours 30 minutes Battery charge cycles 1000 Operative temperature range 0 C to 40 C Size 200x50x200mm w x h x d cabinet 200x55x210mm w x h x d with connectors and feet 360x120x26...

Отзывы: