E
vo
C
LOCK
HIGH PERFORMANCE CLOCK GENERATOR
REVISION P
r
B – DECEMBER 2011
Copyright © 2011, M2Tech Srl
6
M2Tech
www.m2tech.biz
2. Front Panel
1
2
3
4
Figure 1
1) Supply input.
Apply 9V
DC
from the wall adaptor provided in the package of from an
E
vo
S
UPPLY
. Another power supply may be used if necessary, but user must be aware that
in this case the warranty is void. Tip is positive, ring is negative. A minimum current of
500mA is necessary. This input is protected against polarity inversion.
2) MCLK output.
Master clock output dedicated to the
HI
F
ACE
E
vo
. This output delivers
22.5792MHz or 24.576MHz, with 3.3Vpp on 75 Ohms load. This output may also be used
with other equipment, but users must be aware that connecting to a high impedance load
may lead to voltages outside the allowed range for logic circuits. A 75 Ohms cable should
be used for best performance.
3) WCLK output.
Word clock output. This is a very versatile output which delivers all the
most common word clocks, including some “super clocks” at 5.6448MHz (44.1kHz * 128),
6.144MHz (48kHz * 128), 11.2896MHz (44.1kHz * 256) and 12.288MHz (48kHz * 256).
Output impedance can be low-Z (3.3Vpp on high impedance load) or 75 Ohms (3.3Vpp on
75 Ohm load for matched connection). When the latter option is selected, a 75 Ohms
cable should be used for best performance.
4) Power indicator.
Turns on when the stock wall adaptor or the
E
vo
S
UPPLY
are
connected to the
E
vo
C
LOCK
.