background image

BP VCF 113 V1c 

 

Assembly Instructions 

The Band Pass VCF module has no particular requirements not already covered in the 
‘General Guidance on a M²Synth Module Assembly’ booklet included with this kit. 

Calibration 

1.

 

Power up module and allow to ‘warm up’ for 10 minutes 

2.

 

Connect a 440Hz sine wave @ 10V Pk-Pk to Signal input 1. Resonance to 0%, Signal 1 
Level to 100%. 

3.

 

Adjust cut-off to give maximum amplitude output using an oscilloscope. 

4.

 

Adjust Pr1 to give a 10V Pk-Pk output. 

5.

 

Remove the sine wave signal from input 1. Adjust resonance until self-oscillation 
occurs at approximate 10V pk-pk. Connect a frequency meter to the output. 

6.

 

Adjust Cut-off to give 100Hz 

7.

 

Apply a CV of 4V to the COF CV in 1 input 

8.

 

Use Pr2 to calibrate at 1.6kHz (see note below) 

9.

 

Repeat from step 5 until 4V gives 1.6kHz 

Note: If the frequency is flat (<1.6kHz), use Pr2 and make the frequency lower (flatter), if 
above target frequency, use the trimmer to make the frequency even higher, this can be 
counter-intuitive. You will soon get the feel of how much to increase or decrease the 
frequency by. 

 

Specification 

 

Supply v/-12Vdc 

 

Supply c13mA / -16mA 

 

Waveform /-5V 

 

Frequency range: 7Hz to >5.5kHz without any CV applied 

 

Main PCB dimensions 43.5x130mm 

 
 
 
 

Need tech support, post questions on our forum hosted by modwiggler.com 
 

 

 

 

Отзывы: