Configuring the MQ03-Alarm 

In general, the alarm panels are preconfigured with a template according to the needs of each 
customer. If any changes to the basic configurations are needed you can apply them from the 
administrative web site 

https://m2mservices.com/admin

 by logging with your administrative user name 

and password. 

You can find the alarm panel to be configured, using one of the following criteria – account number, 
serial number of the panel, IMEI and etc. 

General settings of MQ03 Alarm 

 

 

Account Number

 – in the field “Account No.” you must fill the number with which the panel will 

report to the central monitoring station. The Account No. must be 4-digits long. By default the 
alarm panel is configured to report from Account No. “0000” 

 

Periodical tests interval

 – in this field you can configure the interval for the periodical test 

messages (in seconds), that the alarm panel will send. 
NOTE: This interval is different from the interval configured for the supervision of the GPRS 
connection – the “heartbeat interval”. The connection is supervised on every 10 minutes by 
default whereas the periodical tests are usually sent every couple of hours.  

 

Configuring a delay in case of mains power outage

 

– 

in the field “Delay”, section “Main Power” 

you can configure the delay (in seconds) after which the device will report the mains power 
outage. 

 

Configuring the Battery level thresholds -

 In section ”Battery”, field “Battery low” you can set a 

low voltage threshold, under which the alarm panel will send “Low Battery” event. In the filed 
“Battery Critical Low” you can set even lower voltage threshold and if the battery voltage goes 
under this level, it will be considered as critically low. 

 
In order to preserve the battery from permanent damage, you can configure the panel to shut down 
automatically if the voltage of the battery drops under the critically low threshold. You can enable that 
feature by checking the “Auto shutdown when battery critical low” checkbox. 

General settings of the partition 

The MQ03-Alarm supports 1 Partition. 
You can configure different Partition settings from RControl Alarm menu, section “Partitions”: 

 

Partition name – 

the name which would be visible in the mobile application.

 

 

Entry time 

(in seconds) 

 

 

Exit time 

(in seconds) – the time interval from the physical arming from a user and the 

arming of the alarm panel. You can choose when the Exit time will be applied – when arming 
from a wireless keyfob, in case of remote arming from the mobile application or both.

 

 

Alarm cycle duration 

(in seconds) – the time interval when the siren will be active after an 

alarm event

 

 

Enable sound indication 

from the siren when the alarm panel is armed and disarmed

 

 

Sound indication from the siren 

in case of tamper alarm

 

Содержание MQ03-Alarm

Страница 1: ...d 1 Kukush Str building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd MQ03 Alarm Installer Manual V 1 2 ...

Страница 2: ...ring detectors 3 SMARTEnroll self learning zones 3 Using the wireless keyfobs 4 Pairing a wireless keyfob 4 Deleting a wireless keyfob 4 Configuring the MQ03 Alarm 5 General settings of MQ03 Alarm 5 General settings of the partition 5 Configuring the zones 6 Zone types 6 ...

Страница 3: ... the alarm panel The tamper can be connected to a zone configured as 24h tamper SMARTEnroll self learning zones The MQ03 Alarm panel supports SMARTEnroll feature preconfigured settings and self learning zones which in most cases eliminate the need of initial programming of the alarm panel This simplifies the installation process in the most commonly used scenario when only instant zones with no en...

Страница 4: ... 2 seconds and then it will start blinking fast This shows that the keyfob has been paired and the procedure was successful You need to repeat this procedure for each additional wireless keyfob separately NOTE 1 If after pressing the white pairing button the RF transceiver does not receive signal from the wireless keyfob within 30 seconds the pairing procedure will be automatically canceled 2 You ...

Страница 5: ... the delay in seconds after which the device will report the mains power outage Configuring the Battery level thresholds In section Battery field Battery low you can set a low voltage threshold under which the alarm panel will send Low Battery event In the filed Battery Critical Low you can set even lower voltage threshold and if the battery voltage goes under this level it will be considered as c...

Страница 6: ...n the alarm cycle time expires the zone restore event will be reported only when the zone is really restored In addition even when there was a restore during the alarm cycle this restore will not be reported until the expiration of the alarm cycle time or until the partition is disarmed Zone types Entry Exit zone The Entry Exit zones can be violated during the entry exit time delay without causing...

Страница 7: ...t zone is violated In this case the alarm panel sends a ContactID event E 374 Exit Error in Zone N reporting the first of all the violated zones which prevent the panel from arming Follow STAY zone This is a Follow zone that is not monitored when the panel is partially armed STAY Arm Instant STAY zone This is an Instant zone that is not monitored when the panel is partially armed STAY Arm ...

Отзывы: