MiNi01-4G
Cellular Communicator with Dial Capture interface
Quick Installation Manual
Connecting the communicator to the alarm panel
(+) 12VDC Power Supply
(-) Ground
Green: RING
Yellow: TIP
White: IN1 (for the optional remote Arming/Disarming feature)
Orange: OUT1
(for the optional remote Arming/Disarming feature)
WARNING: The wiring should be done only when the panel and the
communicator are disconnected from the powerline!
Connect the RING and TIP of the alarm panel to the RING and TIP of the unit
WARNING: Primary use only – NOT to be used with landline!
Having a phone line connected will damage the unit!
Connect the antenna and place it outside of the alarm panel’s box
C and – of the communicator to 12V-15V DC power supply
LED Indicator
Slow flashing – trying to establish connection
Constantly On – connection established at good signal level
Constantly On, blinking every 5 sec – connection established at low signal level
Fast flashing – transferring data
Configuring the alarm panel
Refer to the panel’s installer manual to configure the following options:
Enable the PSTN dialer of the panel
Select DTMF mode (Tone dialing)
Select Contact ID Full communication format
Enter a telephone number for dialing (you can use any number, e.g. 9999999)
Enter a 4-digit account number in the panel.
Configuration guides for popular panels are available at
Troubleshooting the DTMF communication
If you have issues receiving the events, try the following additional settings of the panel:
Disable “Telephone line monitoring”
Disable “Wait for dial tone” option
Use “A” instead of “0” in the account number
If there is more than one partition, enter an account number for each partition
For certain panels, you might need also to specify an account number for the main
partition 0 (sometimes referred as system number)