background image

Installation Precautions

   

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 Use the TOP in an environment that meets the general specification contained

in this manual or datasheet. 

Using the TOP in an environment outside the range of the general specifications

could result in electric shock, fire, erroneous operation, and damage to or

deterioration of the product. 

 Completely turn off the power supply before loading or unloading the module. 

Not doing so could result in electric shock or damage to the product. 

 Make sure all modules of    TOP are loaded correctly and securely. 

Not doing so could cause a malfunction, failure or drop. 

 When install the TOP in environment of much vibration, be sure to insulate the

TOP from direct vibration. 

Not doing so could cause electric shock, fire, and erroneous operation. 

 Be sure to there are no foreign substances such as conductive debris inside

Caution

Wiring Precautions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Completely turn off the external power supply when installing or placing wiring. 

Not doing so could cause electric shock or damage to the product. 

 Make sure that wires are correctly connected to terminals. 

Incorrect connection could result in electric shock or damages to the product

Warning 

 Be sure that wiring is done correctly be checking the product’s rated voltage and 

the terminal layout.

 Incorrect wiring could result in fire, damage, or erroneous operation

 Tighten the terminal screws with the specified torque. 

If the terminal screws are loose, it could result in short circuits, fire, or erroneous

operation. 

 Be sure to ground the FG or (LG) terminal to the protective ground conductor

.

Not doing so could result in erroneous operation.

 

 Be sure there are no foreign substances such as sawdust or wiring debris inside

the module.

    Such debris could cause fire, damage, or erroneous operation

.

 

Caution

 

 

Содержание XTOP15 SERIES

Страница 1: ...Main Module Users Manual XTOP15 12 10 SERIES...

Страница 2: ...t you can take it out and read it whenever necessary Always forward it to the end user Installation Precautions Use the TOP in an environment that meets the general specification contained in this man...

Страница 3: ...does NOT exceed the rating of output module Overcurrent exceeding the rating of output module could cause fire damage or erroneous operation Build a circuit that turns on the external power supply Af...

Страница 4: ...ated 2 Power Cable Wiring Input AC Voltage 85VAC 264VAC Please use noise cut transformer in case that power source includes noise Please separate power source cable from controller s power cable or in...

Страница 5: ...Mode Screen off Time Buzzer Sound Latch Start Buf Latch End Buf Alarm Printer Security Password Touch sensitivity USB setting LCD Brightness and Default Setting 4 Diagnosis Functions Print Test Memor...

Страница 6: ...o foreign substances such as conductive debris inside Caution Wiring Precautions Completely turn off the external power supply when installing or placing wiring Not doing so could cause electric shock...

Страница 7: ...he external power supply off before mounting or removing the module Not doing so could cause failure or malfunction of the module Use a cellular phone or walky talky more than 30cm 11 81 inch away fro...

Страница 8: ...2nd pin and 3rd pin of 9pin COM2 D Sub connector Turn off the power of main module and restart After TOP main module is in the download ready mode remove the short circuit connect 9pin D sub connector...

Страница 9: ...er Bottom Fig 1 Fig 1 XTOP15 series Front Outer and Rear Outer Dimension XTOP15 series panel cut size 357 W X 286 5 H mm Fig 2 Fig 2 XTOP12 10 series Front Outer and Rear Outer Dimension XTOP12 10 ser...

Страница 10: ...Fig 3 Fig 3 XTOP15T Up Down Left Right Outer Dimension Fig 4 Fig 4 XTOP12 10 series Up Down Left Right Outer Dimension...

Страница 11: ...nnector Pins and Signals Pin Number Signal Direction Type Contents 1 NC Not Used 2 RD RxD Input Data Receive 9Pin Female 3 SD TxD Output Data Send 4 DTR Output Data Terminal Ready 5 SG Signal Ground 6...

Страница 12: ...f Connection 1 N N 31 Control Code ASCII Code or HEXA Code Baud Rate 9600 19200 38400 57600 76800 115200bps Data Bit 7 8bit Parity Bit None Odd Even Parity Data Type Stop Bit 1 2bit V COM2 RS 422 485...

Страница 13: ...er Communication and CPU status 5 USB Port USB memory option port Rear View No Title Num of Pin Feature 1 Rubber Packing Shock Absorber for Panel Mounting 2 Power Switch 3 Power Input Terminal 3 Input...

Страница 14: ...ding Resistance Under 100 Atmosphere No Corrosive Gas USB Hardware Specification USB Host Fig 1 Item Specification USB Interface OHCI Specification Version 1 0 Communication method Control Bulk Transf...

Страница 15: ...of connecting Main Module COM1 6P Connector and PC 9P Connector Main Module 6P Male PC 9P Female Male 2 1 4 6 3 5 TOP232C DOWNLOAD CABLE In case of connecting Main Module COM2 9P Connector and PC 9P...

Страница 16: ...J 45 Pin Connector Front 1 8 1 8 Connector Back Pin NO color Signal 1 Orange White TD 2 Orange TD 3 Green White RD 4 Blue Not used 10BaseT 5 Blue White Not used 10BaseT 6 Green RD 7 Brown White Not us...

Отзывы: