M2I CTOP3M Скачать руководство пользователя страница 8

 

 

 

  

Project File Up/Download

 

Meaning  of  ‘Download’  is  transferring  projection  file  data  from  computer  to  TOP  main 

module.   

And ‘Upload’ is transferring data from TOP Main module to computer. 

Main module data will be saved up forever on flash memory of TOP main module    unless 

overwriting. 

It is possible to transfer data on the main menu, communication setup menu, initial setup 

menu,  diagnosis  menu,  and  system  information  menu  after  connecting  download  cable 

between computer and TOP main module.   

it is possible to transfer data on running state 

 

 

 

Font and O/S Download 

Method 1. Main Menu   

-

 

Connect download cable to download port of TOP main module 

-

 

In O/S and Font download menu of TOP Designer on PC, download them to TOP 

main module. 

-

 

After finishing downloading, TOP main module will be reset automatically(When 

Font, TOP will not be reset) 

 

Method 2. OS DOWNLOAD MODE 

-

 

Connect download cable to 9-pin serial port (download port) of TOP main module. 

-

 

Short circuit between 2

nd

 pin and 6

th

 pin of 6pin connector of download cable. 

-

 

Turn  off  power  of  main  module  and  turn  on,  then  [OS  DOWNLOAD  MODE] 

appears on screen. 

-

 

After  TOP  main  module  is  in  the  download  ready  mode,  remove  the  short  circuit 

and connect 9pin D-sub connector to serial port of computer. 

-

 

In O/S and Font download menu of TOP Designer on PC, download them to TOP 

main module. 

-

 

After finishing downloading, TOP main module will be reset automatically 

(If only O.S). 

-

 

Downloadable fonts are bellows. 

  8X8, 8X16, 16 X 16 dot, 16 X 32dot, 32 X 32 dot font 

Содержание CTOP3M

Страница 1: ...oration When using M2I equipment thoroughly read this datasheet and associated manuals introduced in this datasheet Also pay careful attention to safety and handle the module properly Store this datas...

Страница 2: ...t out and read it whenever necessary Always forward it to the end user Installation Precautions Warning Caution Use the TOP in an environment that meets the general specification contained in this man...

Страница 3: ...connected to output does NOT exceed the rating of output module Overcurrent exceeding the rating of output module could cause fire damage or erroneous operation Build a circuit that turns on the exter...

Страница 4: ...ated 2 Power Cable Wiring Input DC Voltage Typically DC24V 20 28V Please be cautious wiring 24V and GND on power supply terminals Please separate power source cable from controller s power cable or in...

Страница 5: ...ode Initial Screen Number Screen Save Buzzer Sound Start of Latch End of Latch Printer Security Password Touch Sensitivity In Case of System Error LCD Brightness Contrast Default Setting 4 Diagnosis F...

Страница 6: ...such as conductive debris inside the module Conductive debris could cause fires damage or erroneous operation Completely turn off the external power supply when installing or placing wiring Not doing...

Страница 7: ...the module Not doing so could cause failure or malfunction of the module Use a cellular phone or walky talky more than 30cm 11 81 inch away from the TOP Not doing so can cause a malfunction Do not str...

Страница 8: ...S and Font download menu of TOP Designer on PC download them to TOP main module After finishing downloading TOP main module will be reset automatically When Font TOP will not be reset Method 2 OS DOW...

Страница 9: ...Outer Dimension Front Rear Side Upper Bottom Fig Front Outer Dimension Fig Rear Outer Dimension...

Страница 10: ...Fig Left Right Outer Dimension Fig Upper Bottom Outer Dimension Panel Cutting size 158 W 126 H mm...

Страница 11: ...te 9600 19200 38400 57600 76800 115200bps Data Type Data Bit 7 8bit Parity Bit None Odd Even Parity Stop Bit 1 2bit Connector Pins and Signals Type Pin Number Signal Direction Contents 9 Pin Female CO...

Страница 12: ...e of Connection 1 N N 31 Control Code ASCII Code or HEXA Code Baud Rate 9600 19200 38400 57600 76800 115200bps Data Type Data Bit 7 8bit Parity Bit None Odd Even Parity Stop Bit 1 2bit Connector Pins...

Страница 13: ...cd 2 Touch Panel Analog 3 Front Sheet Front Vinyl Cover Sheet for Dampproof and Dustproof 4 Status LED Status of Power Fig 2 Rear View No Title Num of Pin Feature 1 Rubber Packing Shock Absorber for P...

Страница 14: ...158 W X 126 H Mm General Specification Item Specification Input Voltage DC type DC 24V 20 28V Power Consumption 15W Input Power Cable AWG18 AWG26 Noise Immunity Impulse Noise 1000Vp p Pulse width 1 In...

Страница 15: ...5 6 7 SG 8 20 Download Interface RS232C Download Connection RS232C In case of connecting Main Module 6P Connector and PC 9P Connector Main Module 6P Male PC 9P Female In case of connecting Main Modul...

Страница 16: ...Head Office Kyonggi Venture Anyang Technical Center 13th Floor 572 5 Anyang 8 Dong Dongan Gu Anyang Si Kyonggi Do Korea 431 060 TEL 82 31 465 3366 FAX 82 31 465 3355 http www m2i co kr M2I Corporation...

Отзывы: