7
voltage also passes through the transformer. The emitter of the device is grounded to its flange base (header) which in
turn is attached to the copper heat spreader. There is a common ground then in the system between the chassis, the PC
board and the heat sink system. This ground connection is very important for heat transfer and also for total device current
flow.
On the output side of the device, large PC board traces provide high power, high current connections to two cross
-connected 10 ohm coax line sections. These line sections form a 9:1 Impedance step and transform the very low drain
impedance up to about 25 ohms, balanced. A high current dc ferrite choke brings the 50 VDC to the drain side of the de-
vice. Various tuning, blocking and bypassing capacitors aid in the balanced tank circuits transition through a coax line to 50
ohms, unbalanced. Following the tank circuit is a multi-section low pass filter and harmonic trap. The filter is followed by a
high power vacuum relay, the VSWR bridge and finally the output SO-239 or female ‘N’ connector.
OVERVIEW
O
V
E
R
V
IE
W
Содержание 2M-1K2
Страница 11: ...11 TROUBLESHOOTING TROUBLESHOOTING...
Страница 12: ...12...
Страница 13: ...13...
Страница 19: ...19...