Effect of vacuuming will be influenced by altitude, and when the data
is above -88, it will have the best vacuuming effect.
(
6
) Normally, the air will be released by 30s vacuum time, and then
the laminating plate will slowly press down with pressure of 5-6kg. After
30s laminating time, the plate will rise up and the vacuum meter go
zero. Then the door can be opened to take the screen out.
(
7
)
The screen need test after lamination.
4、Debubbling
1. Hold the handle and counterclockwise rotate it from the right to the
left to open the door.
<7>