2. Put the positioned screen into the special silicone pad for pressing the

screen, put the glass panel down, then put it into the fitting cabin of the

machine, and close the fitting door.

*The placement of the screen is very important, which directly affects the final yield.

The edge of the display window of the screen should be aligned with the edge of the

sponge pad, so as to completely avoid the cable. Pressure leads to waste screen. (If
you have other questions that you don

t understand, you can contact the after-

sales technicians to answer for you.)

3. Select "f defoaming", press start to start the automatic screen

pressing.

4. After starting, note that the negative pressure value on the display screen

continues to rise, which means normal. If the pressure value does not rise

after starting, please contact after-sales technicians to solve it for you.

Содержание MT-16

Страница 1: ...MT 16 airbag laminating defoaming machine User Manual 1 safety rules 2 Specifications 3 Steps for usage 4 devices care...

Страница 2: ...t damage or endanger personal safety C Non professionals are strictly forbidden to open the electric box 2 Specifications Equipment power supply AC250V optional AC110V AC220V Working environment 20 30...

Страница 3: ...2 Press Parameter Setting to set device parameters 0 0 40 0...

Страница 4: ...sure screen and matters needing attention 1 Use the screen positioning mold to carry out preliminary positioning and bonding of the liquid crystal and the cover plate Note that after the cover and the...

Страница 5: ...aligned with the edge of the sponge pad so as to completely avoid the cable Pressure leads to waste screen If you have other questions that you don t understand you can contact the after sales technic...

Страница 6: ...is above 88 Usually the air in the cabin can be sucked out within 45 seconds of vacuum time and then the airbag is slowly pressed down The bonding time is 45 seconds After the bonding is completed th...

Страница 7: ...n the display screen The door can only be opened when the air pressure is zero 3 Working mode 1 laminating mode Press the start button the device can start to work the machine starts to vacuumize runs...

Страница 8: ...ce starts to deflate the positive pressure value returns to zero and the defoaming is completed Observe the pressure gauge during the defoaming process no air leakage 3 laminating defoaming mode Press...

Страница 9: ...The defoaming time can be adjusted according to the size of the bubbles on the screen at least 5 to 10 minutes 4 devices care Maintenance item Precautions for maintenance Cavity Check whether there ar...

Отзывы: