Usually, the air in the cabin can be sucked out within 30 seconds of vacuum

time, and then the airbag rises slowly, and the bonding time is 45 seconds.

After the screen is pasted, a screen measurement is required

3. Take out the final product and check whether the display and touch are

normal.

*Before opening the hatch every time, check whether there is gas in the

cavity. The checking method is to observe the vacuum value on the screen,

and the door can only be opened when the air pressure is zero.

3.Working mode

1.Built-in laminating mode

Press the start button, the device can start to work, the machine starts to vacuum,

runs to the set lamination time, the vacuum value jumps, at this time the equipment

starts lamination, when the set lamination time is reached, the equipment starts to

deflate, and the vacuum value returns to zero , the fit is complete.

1. Outside laminating mode

Содержание MT-13

Страница 1: ...MT 13 Airbag all in one Laminating Machine User Manual 1 safety rules 2 Specifications 3 Steps for usage 4 devices care...

Страница 2: ...t must be well grounded Poor grounding may cause equipment damage or endanger personal safety C Non professionals are strictly forbidden to open the electric box 2 Specifications Equipment power suppl...

Страница 3: ...1 After turning on the machine set Chinese and English settings and press the Chinese and English keys to switch 2 Press Parameter Setting to set device parameters...

Страница 4: ...45 seconds and bonding time 45 seconds No special requirements please do not adjust the parameters without authorization if you need to change the parameters please contact the manufacturer after sale...

Страница 5: ...er with your fingers and then tap the LCD in the middle of the bottom of the mold to make the middle stick That s right this is extremely important 1 Put the positioned screen into the special silicon...

Страница 6: ...the automatic screen pressing 4 After starting note that the vacuum value on the display screen continues to rise which means normal If the pressure value does not rise after starting please contact...

Страница 7: ...her there is gas in the cavity The checking method is to observe the vacuum value on the screen and the door can only be opened when the air pressure is zero 3 Working mode 1 Built in laminating mode...

Страница 8: ...ts to vacuum runs to the set lamination time the vacuum value jumps at this time the equipment starts lamination when the set lamination time is reached the equipment starts to deflate and the vacuum...

Страница 9: ...ce Cavity Check whether there are sundries and if so please clean them up in time Equipment life When the machine is not in use the power must be turned off to make the equipment last longer Cooling n...