Website: www.metertreater.com
Meter Treater Inc.: 1349 South Killian Drive • Lake Park, FL 33403
Sales: 561.845.2007 Toll: Free: 800.638.3788 Fax: 561.848.2372
Email: [email protected]
MT-BPTSERIES-3/18
The
BPT Series
is a
Transient Protection System
that provides heavy-duty
surge protection and filtering for industrial and commercial sites against the
harmful effects of transient energies induced on AC power lines. The BPT’s unique
construction allows it to deliver low clamping voltages while
safely handling
large surge currents
. Configured for parallel installation, units install quickly and
easily. All models are suitable for Type 1 or Type 2 service panel applications.
On-board diagnostics
include a panel display equipped with LED indicators that
continuously monitor the operational
status of the entire unit
. An
Audible
Alarm
is standard with switch positions for test, disable and enable. A
Surge
Counter
and a set of NO/NC dry contacts are also standard. A Remote Monitor
and/or Filter are available as options.
Weather Resistant models available
in a NEMA 4X housing with internal
diagnostics for harsh environments. Audible Alarm and Surge Counter are not
included with the NEMA 3R model.
Product Specifications
I
n
Max Surge Current
Fusing
Short Circuit Current
Enclosure Ratings
10/20 kA
300kA per Phase
Coordinated Surge & Thermal
100kA RMS Symmetrical Amps
NEMA 4, 4X & NEMA 12
Model Number Service Voltage MCOV L - N L - G N - G L - L
BPTXXX/120-10-#-1
BPTXXX/120-SP-#-1
BPTXXX/120-3W-#-1
BPTXXX/120-3H-#-1
BPTXXX/240-3D-0-1
BPTXXX/220-3W-#-1
BPTXXX/230-3W-#-1
BPTXXX/240-3W-#-1
BPTXXX/277-3W-#-1
BPTXXX/480-3D-0-1
120 Volt Single Ø
120/240 Volt Split Ø
120/208 Volt 3Ø Wye
120/240 Volt 3Ø HL Delta
240 Volt, 3Ø Delta
220/380 Volt, 3Ø Wye
230/400 Volt, 3Ø Wye
240/415 Volt, 3Ø Wye
277/480 Volt, 3Ø Wye
480 Volt, 3Ø Delta
700V
700V
700V
700V
N/A
1000V
1000V
1000V
1000V
N/A
150Vac
150Vac
150Vac
150/320Vac
320Vac
320Vac
320Vac
320Vac
320Vac
520Vac
600V
600V
600V
600/1000V
N/A
1000V
1000V
1000V
1000V
N/A
600V
600V
600V
600/1000V
1000V
1000V
1000V
1000V
1000V
1800V
VPR
Mechanical/Environmental Specifications
Diagnostics
Safety Standards
Operating Frequency
LED, Audible Alarm, Surge Counter
UL 1449 (most current)
50/60 Hz
N/A
1200V
1200V
1200/1500V
1200V
2000V
2000V
2000V
2000V
4000V
Dimensions
Typical Installations
1.
Replace XXX with:
desired kA rating per phase: 100 for 100kA or 200 for 200kA or 300 for 300kA. 2.
Replace # with:
F if filtering is required (available option on WYE Models only).
3.
Add:
/RM at the end of the Model Number for the Remote Monitoring option.
4.
ENCLOSURE HOUSING OPTIONS:
Add /POL to the end of the Model Number for NEMA 4X
NonMetallic or /SS for NEMA 4 Stainless Steel or /WP for Weatherproof.
Commercial/Industrial Panel
Surge Protection Device
BPT Series
(Diagrams not drawn to scale)
All product dimensions provided are ± 0.125