M-system VOS2T-R Скачать руководство пользователя страница 4

VOS2T-R

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-4766  Rev.6  P. 4 / 4

MAINTENANCE

 

MECHANICAL PARTS

• Check that screws are fastened tightly and if some of 

them are loosened, be sure to re-tighten them.

   If you find the connecting pin loose, go through “ADJUST-

MENT PROCEDURE” again.

• Inspect visually that the connecting section of levers is 

stable and smooth.  Check also that the connecting pin or 
lever is not worn.  If it is, it must be replaced.  Consult M-
System or local representative.  If the abrasion advances 
fairly quickly, there may be a problem in the link mecha-
nism (e.g. connecting pin position)

• If the VOS2T-R is installed outside the building or where 

it is subject to water or metallic dust particles, check that 
there is no crack or bruise on the gasket.  If you find any, 
consult M-System or local representative.

• Consult M-System or local representative also for 

inspection of packing (O-ring) in the moving parts.

 

ELECTRICAL PARTS

• Check first the mechanical parts as above.
• Change actuator positions and input 0%, 25%, 50%, 75% 

and 100% signals.  Check the output with respective input 
value is within allowance indicated in the specifications.  
If not, go through “ADJUSTMENT PROCEDURE” again.

LIGHTNING SURGE PROTECTION

M-System offers a series of lightning surge protectors for 
protection against induced lightning surges.  Please contact 
M-System to choose appropriate models.

Содержание VOS2T-R

Страница 1: ...king on the product to be exactly what you ordered POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVES When the unit is mounted onto a grounded metal bracket insert a noise filter for the output COSEL Noise Filter Model NAC 04 472 or equivalent is recommended GENERAL PRECAUTION Cut power supply to the unit before wiring to it ENVIRONMENT Inside building If outside keep away from direct sun light Opera...

Страница 2: ... the connecting pin to the VOS2T R side lever utiliz ing the nailed nut and the nut as in Figure 3 The actuator side lever should be threaded with the connecting pin but left loose The nail could be positioned in either side of the lever however it is limited to one side at the extreme end of the lever hole ø5 0 03 0 Lever Actuator Side Connecting Pin Nailed Nut Lever VOS2T R Side Nut with Washer ...

Страница 3: ...le with a wrench 7 mm or by twisting the indicator with your hand so that the VOS2T R outputs approx 12mA If you are using levers to link tighten the screw for lever now torque 2 4 3 1 N m If you are not using a lever fix the coupling now 5 Check the indicator and adjust its angle after loosening its screw M2 6 if necessary Make sure that it is tightened again after adjustment HOW TO ADJUST ZERO A...

Страница 4: ...em in the link mecha nism e g connecting pin position If the VOS2T R is installed outside the building or where it is subject to water or metallic dust particles check that there is no crack or bruise on the gasket If you find any consult M System or local representative Consult M System or local representative also for inspection of packing O ring in the moving parts ELECTRICAL PARTS Check first ...