SETTING FLOWCHART

POWER SUPPLY ON

 

INITIAL SETTING FLOW CHART

INITIAL SETTING COMPLETE

Set the following parameters in the setting mode.

     • Retroactive time
     • Transition ramp rate 
     • LED brightness

Power Supply ON

PV Input

PV LED

ON at startup

Measuring in progress

 

SETTING MENU

When the power supply is turned on, the SM10 starts at the measuring mode.
Pressing and holding the indication selector button (IND button) for longer then 3 seconds turns the module into the setting mode.

Measuring stopped

*

1

Mode transition

Back to Measuring Mode

Retroactive 

Time

ON

SETTING MODE

IND

IND

Press

IND

Press/Hold

for 3 sec.

OUT

Press/Hold

for 1 sec.

OUT

Press/Hold

for 1 sec.

CAS Input

CAS LED

ON

IND

Press

Press

IND

IND

Press

Press

Transition

Ramp Rate

ON

MV Input

Back to PV input

MV LED

ON

IND

Press

MEASURING MODE

*

1. Value before interruption is held.

Output Manual Switching

CAS/MAN LED

CAS

MAN

LED status at the last state 
before power interruption is 
reproduced
(above: CAS input to MV output)

RA

IND

Press/Hold

for 3 sec.

LED

Brightness

Blinking

RA

RR

Output Mode Switching

CAS/MAN LED

CAS

MAN

Pressing OUT button reverses
the previous LED status.
(above: MV output by UP/
DOWN operation button 
setting)

IND

OUT

IND Button

OUT Button

Содержание SM10

Страница 1: ...COMPONENT IDENTIFICATION 3 EXTERNAL DIMENSIONS TERMINAL ASSIGNMENTS 3 INSTALLATION 4 CONNECTION DIAGRAM 5 PREPARATION WIRING TO THE UNIT 5 LIGHTNING SURGE PROTECTION 5 SETTING FLOWCHART 6 SETTING MODE 7 MANUAL LOADER with 4 digit digital meter LED bar indicator MODEL SM10 OPERATING MANUAL ...

Страница 2: ...ons subject to direct sunlight or where excessive dust dirt or metal particles are present This unit is a precision instrument Do not store or use it where large shocks or excessive vibration can occur Do not store or use this unit in environments subject to chemical evaporation such as that of organic solvents or where there are chemicals and or acids present in the environment Do not use paint t...

Страница 3: ...MV bargraph meter 8 Retroactive time LED RA 9 Transition ramp rate LED RR 10 Input indication selector IND 11 CAS MAN indicator LED 12 CAS MAN selector OUT 13 Manual operation button UP 14 Acceleration button FAST Acclerates the operation by pressing simultaneously with UP or DOWN button 15 Manual operation button DOWN 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 40 41 42 4...

Страница 4: ...enance purpose e g wiring removing or install ing HOW TO MOUNT THE UNIT ON A PANEL 1 Remove both mounting brackets 2 Detach the terminal cover and insert it first and then the module itself into the cutout hole The cover is slightly wider than the module 3 Put and slide the brackets back into the holes at the top and the bottom and tighten them until the module is firmly fixed HOW TO REMOVE THE TE...

Страница 5: ...with CAS input 2 PREPARATION WIRING TO THE UNIT POWER SUPPLY Confirm the power input rating marked on the product 1 Remove the terminal cover 2 Loosen three screws at the power supply terminals 3 Connect power input and protective earth cables to them 4 Replace the terminal cover I O SIGNALS Refer to the following example of connecting CAS input sig nal 1 Turn off the power supply and remove the t...

Страница 6: ... stopped 1 Mode transition Back to Measuring Mode Retroactive Time ON SETTING MODE IND IND Press IND Press Hold for 3 sec OUT Press Hold for 1 sec OUT Press Hold for 1 sec CAS Input CAS LED ON IND Press Press IND IND Press Press Transition Ramp Rate ON MV Input Back to PV input MV LED ON IND Press MEASURING MODE 1 Value before interruption is held Output Manual Switching CAS MAN LED CAS MAN LED st...

Страница 7: ... next item Refer to the next page for the definitions of Retroactive Time and Transition Ramp Rate LED BRIGHTNESS range 1 2 3 1 Confirm that the unit is in the setting mode 2 Press IND button one or more times to choose the LED RA in blinking state 3 The digital meter shows the present setting 4 Use UP DOWN button to set a desired value on the digital meter 5 Press IND button to move on to the nex...

Страница 8: ...cator is turned on and the MV output tracked down by the retroactive time setting 100 output at the point a in the above example is provided Though the above example shows no manual control the MV value can be changed to a desired value by manipulating UP DOWN buttons during this period 2 The manual control mode is cancelled when the manual command input is turned off Both CAS and MAN indicators t...

Отзывы: