background image

R9WTU-ED

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-6225  Rev.1  P. 2 / 4

COMPONENT IDENTIFICATION

Terminal Block, Discrete Outputs

Output Status Indicator LED

Input Status Indicator LED

Terminal Block, Discrete inputs

COM COM

DI1 DI2

2

1

11

10

COM COM

DI3 DI4

4

3

13

12

COM COM

DI5 DI6

6

5

15

14

COM COM

DI7 DI8

8

7

17

16

NC

NC

9

18

NC DO8+

NC DO8-

8

9

17

18

DO7+ DO6+

DO7- DO6-

6

7

15

16

DO5+ DO4+

DO5- DO4-

4

5

13

14

DO3+ DO2+

DO3- DO2-

2

3

11

12

DO1+

DO1-

1

10

 

I/O STATUS INDICATOR LED

Discrete I/O extension units have LED indi-
cators showing I/O signal status.
Contact ON : LED ON
Contact OFF : LED OFF

TERMINAL ASSIGNMENTS

14

5

6

DI5

COM COM

15

DI6

16

17

18

7

8

9

DI7

DI8

NC

COM COM

10

1

2

DI1

COM COM

11

DI2

12

13

3

4

DI3

DI4

COM COM

NC

   

ID 

  

  

ID 

 

  

  

 

  1 

COM  Input comon 

10 

DI1  Input 1ch

  2 

COM  Input comon 

11 

DI2  Input 2ch

  3 

COM  Input comon 

12 

DI3  Input 3ch

  4 

COM  Input comon 

13 

DI4  Input 4ch

  5 

COM  Input comon 

14 

DI5  Input 5ch

  6 

COM  Input comon 

15 

DI6  Input 6ch

  7 

COM  Input comon 

16 

DI7  Input 7ch

  8 

COM  Input comon 

17 

DI8  Input 8ch

  9 

NC 

Unused 

18 

NC  Unused

 DISCRETE INPUT

5

14

13

DO5–

DO5+ DO4+

4

DO4–

3

2

1

12

11

10

DO3– DO2– DO1–

DO3+ DO2+

9

18

17

NC

NC DO8+

8

DO8–

7

6

16

15

DO7– DO6–

DO7+ DO6+

DO1+

   

ID 

 

 

ID 

 

  

 

 

  1 

DO1–  Output 1ch– 

10  DO1+  Output 1ch+

  2 

DO2–  Output 2ch– 

11  DO2+  Output 2ch+

  3 

DO3–  Output 3ch– 

12  DO3+  Output 3ch+

  4 

DO4–  Output 4ch– 

13  DO4+  Output 4ch+

  5 

DO5–  Output 5ch– 

14  DO5+  Output 5ch+

  6 

DO6–  Output 6ch– 

15  DO6+  Output 6ch+

  7 

DO7–  Output 7ch– 

16  DO7+  Output 7ch+

  8 

DO8–  Output 8ch– 

17  DO8+  Output 8ch+

  9 

NC 

Unused 

18 

NC  Unused

 

 DISCRETE OUTPUT

No.

FUNCTION

FUNCTION

FUNCTION

FUNCTION

No.

No.

No.

INSTALLATION

 

WALL MOUNTING

Insert the provided mounting adaptors into upper side of 
the unit, and pull out those on the lower side.  Fasten the 
M4 screw to the hole (4.5 mm dia.) of each adaptor. (torque 
1.4 N∙m)
To remove the adaptor, pull it out while squeezing the latch-
es as shown in the figure below.

push

push

 

DIN RAIL MOUNTING

Set the unit so that its mounting adaptors are at the bot-
tom.  Position the upper hook at the rear side of the unit 
on the DIN rail and push in the lower.  When removing the 
unit, push down the adaptors utilizing a minus screwdriver 
and pull.

DIN Rail (35 mm wide)

Mounting Adaptor

Содержание R9WTU-ED

Страница 1: ... POWER CONSUMPTION AC 2VA DC 1 5W GENERAL PRECAUTIONS Before you remove or mount the unit turn off the power supply and input signal for safety ENVIRONMENT Indoor use Do not install the unit where it is directly exposed to rain water droplets or sunlight When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the u...

Страница 2: ...nput 6ch 7 COM Input comon 16 DI7 Input 7ch 8 COM Input comon 17 DI8 Input 8ch 9 NC Unused 18 NC Unused DISCRETE INPUT 5 14 13 DO5 DO5 DO4 4 DO4 3 2 1 12 11 10 DO3 DO2 DO1 DO3 DO2 9 18 17 NC NC DO8 8 DO8 7 6 16 15 DO7 DO6 DO7 DO6 DO1 ID ID 1 DO1 Output 1ch 10 DO1 Output 1ch 2 DO2 Output 2ch 11 DO2 Output 2ch 3 DO3 Output 3ch 12 DO3 Output 3ch 4 DO4 Output 4ch 13 DO4 Output 4ch 5 DO5 Output 5ch 14 ...

Страница 3: ...CONNECTION DIAGRAM 1 5 10 2 6 4 7 13 8 14 12 15 11 16 17 COM COM COM COM COM COM DI2 DI1 DI3 DI4 DI5 DI6 DI7 DI8 Control Circuit INPUT Excitation Supply COM 3 1 5 10 2 6 4 7 13 8 14 12 15 11 16 17 3 COM DO6 DO6 DO7 DO7 DO8 DO8 DO1 DO1 DO2 DO2 DO3 DO3 DO4 DO4 DO5 DO5 1 10 8 17 COM DI1 DI8 COM DISCRETE INPUT DISCRETE OUTPUT Control Circuit OUTPUT 10 1 DO1 DO1 17 8 DO8 DO8 EXTENSION CONNECTOR 1 10 1 ...

Страница 4: ...ore the two locks of the multi power monitoring unit to the front position 5 Mount the combined unit on a DIN rail Note When you remove or mount the unit turn off the power supply and input signal for safety Lock Cap WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size Spade tongue type is also applicable Applica...

Отзывы: