R80NCIT1

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7026-B  P. 3 / 15

COMPONENT IDENTIFICATION

Power Supply/
Exc. Supply Connecor

PC Configurator Connector

Status Indicator LED

IP Address /
Station No. Rotary SW

CC-Link IE TSN Communication
RJ-45 Modular Jack

Internal Bus Connector

PWR

D LINK
ERR

CONFIG

SD

RD

RUN

STATION No.

X16

X1

 

STATUS INDICATOR LED

ITEM

ID

COLOR

FUNCTION

STATUS

DESCRIPTION

Status 
Indicator

RUN

Green

Device State

ON

Normal

OFF

Device error

RD

Green

Receiving Data

ON

Receiving

OFF

Unreceived data

SD

Green

Sending Data

ON

Sending

OFF

Unsent

D LINK

Green

Data link 
Transmitting

ON

In action (Cyclic transmitting)

Blinking

In action 
(Stopping cyclic transmitting)*

1

OFF

Not complied with

ERR

Red

Error

ON

Critical failure*²

Blinking

Minor failure*³

OFF

Normal

CN1

LINK

Green

CN1 Linking Up

ON

Linking up

OFF

Link-down

L ER

Red

CN1 Receiving Data

ON

Abnormality receiving data

OFF

Normality receiving data

CN2

LINK

Green

CN2 Linking Up

ON

Linking up

OFF

Link-down

L ER

Red

CN2 Receiving Data

ON

Abnormality receiving data

OFF

Normality receiving data

*1. Setting as reservation area, stop linking and etc..
*2. Host communication error, internal bus communication error, and etc..
*3. Non-volatile memory error, IP address / station No. setting rotary switch has been changed after turning on the module.

 

IP ADDRESS / STATION NO. SETTING ROTARY SW

Set the fourth octet of IP address and station No. with two rotary switches. The upper rotary SW sets the upper digits (MSB),
and the lower rotary SW sets the lowest digit (LSB) with hexadecimal (configurable range is 1 to 254).
Turn off the power supply when setting IP address / Station No. setting Rotary SW, as the setting is activated when turning
on the power supply.
Confirm available station numbers in the manual of the master unit (Factory default setting: 01H).
IP address: The first to third octet are common with the first to third octet of IP address for master station.

For setting MSB of Station No. (×16)

For setting LSB of Station No. (×1)

8

67

345

2

10

F E D C B A

9

8

67

345

2

10

F E D C B A

9

* Station No. setting example
IP address / Station No. setting rotary SW are set with hexadecimal.
For example, in the case of setting station No. 175, Set the Station MSB: A and LSB: F. 

Содержание R80NCIT1

Страница 1: ...info m system co jp EM 7026 B P 1 15 OPERATING MANUAL POWER NETWORK MODULE CC Link IE TSN MODEL R80NCIT1 CONTENTS BEFORE USE 2 POINTS OF CAUTION 2 INSTALLATION 2 COMPONENT IDENTIFICATION 3 TERMINAL C...

Страница 2: ...DC 10 approx 12W internal power max current 1 6 A Excitation supply excitation for I O module 24V DC 10 operational current 10 A From power supply excitation supply connector via con nector for inter...

Страница 3: ...OFF Link down L ER Red CN2 Receiving Data ON Abnormality receiving data OFF Normality receiving data 1 Setting as reservation area stop linking and etc 2 Host communication error internal bus communic...

Страница 4: ...N No 1 24V Power supply 24V DC 2 0V Power supply 0V DC 3 Excitation supply 24V DC 4 Excitation supply 0V DC 5 FE1 Grounding 1 2 3 4 5 PC CONFIGURATOR The following parameter items can be configured wi...

Страница 5: ...XC SUPPLY 24V 24V 0V FE1 POWER EXC SUPPLY Regarding CN1 and CN2 of RJ 45 connector for CC Link IE TSN network there is no restriction for connection order CONNECTOR CONNECTOR WIRING INSTRUCTIONS TENSI...

Страница 6: ...H1 CH2 CH3 CH4 Module address 3 R80UST4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 Module address 4 R80YST4N 0 15 RWw n 0 2 4 6 8 10 12 Module address 0 Module address 1 R80DAT16A2 R80DCT16A2 Di16 points Do16 po...

Страница 7: ...TH I O MODULES When the communication between the network module and the I O modules is lost due to an error in an input module the last process values are held until the communication is re establish...

Страница 8: ...GX Works3 REGISTRATION FOR PROFILE This unit supports CC Link Family system profile CSP CSP can be downloaded from the M System s web site https www msystem co jp or CC Link Partner Association s web...

Страница 9: ...on Local Station and Remote Station R30NCIT1 are connected by Ethernet cable CN1 and CN2 of CC Link IE TSN Network RJ 45 modular jacks can be connected in any order Before wiring make sure to turn off...

Страница 10: ...x 81 6 6659 8510 E mail info m system co jp EM 7026 B P 10 15 4 In the following window when Module Label Not use is displayed in Module Setting click Setting Change to open the option window and chan...

Страница 11: ...Double click Module Configuration in the Navigation window to open the Module Configuration window According to the real PLC configuration select the module from POU List of the Element Selection wind...

Страница 12: ...6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 7026 B P 12 15 7 Set Station Type to Master Station Network No to 1 in Required Settings 8 Click Detailed Setting of Network Configuration...

Страница 13: ...6 B P 13 15 According to the real system configuration select the device from Module List and drag and drop it to the device configura tion diagram Click Close with Reflecting Setting When CSP not reg...

Страница 14: ...7 0063 JAPAN Phone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 7026 B P 14 15 Assign link devices RX RY RWr RWw to devices of the CPU unit click Apply to close the window Click 10...

Страница 15: ...u Osaka 557 0063 JAPAN Phone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 7026 B P 15 15 11 Click Write to PLC in Online on menu bar to open Online Data Operation window Select Chec...

Отзывы: