MEChATROLINK RELATED COMMANDS

 

MECHATROLINK DATA LINK LAYER COMMAND DESCRIPTIONS

The R7ML, Intelligent I/O, performs the connection-type communications according to MECHATROLINK protocol.
The following tables explain Data Link Layer Commands supported by the R7ML.

• MDS Command (04H) Data Format

Byte

COMMAND

RESPONSE

REMARKS

0

MDS (04H)

S (0) (90H)

Message Data Search (MDS) Command: Read the ID from the slave station
S (0): Response to MDS

1

0

ID1 (00H)

2

0

ID2 (80H)

Intelligent I/O specified

3

0

0

4

0

0

5

0

0

6

0

0

7

0

0

8

0

0

9

0

0

10

0

0

11

0

0

12

0

0

13

0

0

14

0

0

15

0

0

16

0

0

17

:

31

0

:

0

0

:

0

Byte 17 through 31 are always 0 in the 32-byte mode.
These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the 17-byte 
mode.

• CDRW Command (03H) Data Format

Byte

COMMAND

RESPONSE

REMARKS

0

CDRW 

(03H)

ACK 

(01H)

Cyclic Data Read/Write (CDRW) Command: Link transmission
Acknowledge (ACK): Positive response to CDRW

1

CMD

RCMD

CMD: Application Layer Command
RCMD: Response to Application Layer Command

2

:

16

Byte 2 through 16 depend upon the Application Layer Command type.

17

:

31

Byte 17 through 31 depend upon the Application Layer Command type.
These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK- II in the 17-
byte mode.

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Содержание R7ML-SV4

Страница 1: ...E requirements in regard to the whole system and employ additional protective measures to ensure CE conformity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product...

Страница 2: ...SD Green Turns on when the module is transmitting RD Green Turns on when the module is receiving STATION ADDRESS Station Address is selected between 60H and 7FH Intel ligent I O in hexadecimal Certai...

Страница 3: ...rate factory default 80 msec Sensor type and range Before starting programming turn on the front SW1 5 6 7 8 For more information about the programming using the R7CON please refer to the R7CON Users...

Страница 4: ...ion FG terminal is NOT a protective conductor terminal 1 VH0 10 VL0 11 I0 2 COM0 INPUT 0 3 VH1 12 VL1 13 I1 4 COM1 INPUT 1 6 VH2 15 VL2 16 I2 7 COM2 INPUT 2 8 VH3 17 VL3 18 I3 9 COM3 INPUT 3 Input Con...

Страница 5: ...e SRD SRD SLD SRD SRD SLD Slave SRD SRD SLD MECHATROLINK Cable MECHATROLINK Cable MECHATROLINK COMMUNICATION MECHATROLINK I Baud rate 4 Mbps Transmission distance 50 m max Distance between stations 30...

Страница 6: ...0 0 11 0 0 12 0 0 13 0 0 14 0 0 15 0 0 16 0 0 17 31 0 0 0 0 Byte 17 through 31 are always 0 in the 32 byte mode These bytes are unavailable for MECHATROLINK I or MECHATROLINK II in the 17 byte mode CD...

Страница 7: ...ESPONSE REMARKS 0 CDRW 03H ACK 01H Cyclic Data Read Write CDRW Command Link transmission Acknowledge ACK Positive response to CDRW 1 ID_RD 03H ID_RD 03H Read ID ID_RD Command Read out the device ID 2...

Страница 8: ...on cycle 8 0 0 9 0 0 10 0 0 11 0 0 12 0 0 13 0 0 14 0 0 15 0 0 16 0 0 17 31 0 0 0 0 Byte 17 through 31 are always 0 in the 32 byte mode These bytes are unavailable for MECHATROLINK I or MECHATROLINK I...

Страница 9: ...id Command Command is not supported Warning 02H Command Not Allowed Command execution conditions are not met Warning 03H Invalid Data Data in the command is not correct Warning 04H Synchronization Err...

Страница 10: ...et R7ML EC16x R7ML EC8x Output data are repeated EXT IN HI Extension data high 8 bits R7ML EA16 Bit 8 through 15 data are set R7ML EC16x Output data are repeated R7ML EA8 R7ML EC8x Unused Extension Ou...

Отзывы: