FUNCTIONAL BLOCK: fbCNT [0...7]

fbCNT[0...7] (Object ID : 17...24)

nv 36

...nv 43

nviCNTIn
SNVT_switch

nv 44

...nv 51

nviCNTCtrl
SNVT_switch

nv 52

...nv 59

nvoCNTOut
SNVT_count_32
SNVT_count_f

Set the initial value at nviCNTCtrl at the startup

Set count logic (ON or OFF)

Set operating mode

Set network variable type nvoCNTOut
Set the maximum count
Set the value when fbCNT[ ] is reset

fbCNT[ ] :
     SCPTdirection
nviCNTIn :
     SCPTinvrtOut
nviCNTCtrl :
     SCPTpwrUpState
nvoCNTOut :
     SCPTnvType
     SCPTmaxRnge
     SCPTsetpoint

Network Variables

Configuration Properties

• Network Variables

NETWORK
VARIABLE

TYPE
{ Range }
{ Default }

EXPLANATIONS

nviCNTIn

{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}

Counted object

nviCNTCtrl

{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}

Controls operation of fbCNT
0.0 0 : Stop counting
100.0 1 : Start counting
Invalid : Reset count value

nvoCNTOut

{SNVT_count_32}
{0...999 999 999}
{0}
{SNVT_count_f}
{0...999 999}
{0}

Number of ON counts or accumulated time of ON status at nviCNTIn or 
the input terminal

Содержание R7L-DA16

Страница 1: ...nts When counter pulse and discrete are mixed and acquired make sufficient consideration to them Before you remove the unit or mount it turn off the power supply and input signal for safety ENVIRONMEN...

Страница 2: ...Used to show discrete input signal status ON LED ON OFF LED OFF Note For firmware version 0 14 or smaller when the discrete inputs are commissioned by LonMaker the LEDs indi cate the status of them S...

Страница 3: ...ide 54 2 13 17 66 4 5 6 7 1 2 3 10 11 12 13 2 3 4 1 15 16 17 18 7 8 9 6 14 5 3 12 5 5 22 50 1 97 18 5 73 115 4 53 7 M3 SCREW TERMINALS for LONWORKS POWER 18 M3 SCREW TERMINALS for INPUT 6 24 6 24 CONN...

Страница 4: ...ONNECTION HOST PC LONWORKS R7L LONWORKS R7L LONWORKS Terminator WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal si...

Страница 5: ...PToemType SCPTserialNumber Extension module setting Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variable...

Страница 6: ...0 0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration property is changed Network variables are sent out in the specified intervals even when...

Страница 7: ...CNTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Confi...

Страница 8: ...N 1 Accumulated time of ON status Bit 7 Memory storage at the non volatile memory 0 Count retained in the memory and preset at the startup 1 Count always reset to 0 Bit 8 through 15 Invalid Minimum in...

Страница 9: ...set signal Set output at nvoDIStat Combination Mode Refer to the table in the next page RS flip flop set signal Reset output at nvoDIArm fbDI SCPTdirection nvoDIStat SCPTinvrtOut nvoDIArm SCPTinvrtOut...

Страница 10: ...NETWORK VARIABLE TYPE Range Default EXPLANATIONS nvoDIStat SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Contact input nvoDIStat and nvoDIArm Reference Table X0 X2 X4 X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF...

Страница 11: ...iCMPIn2 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Connects to the network variable to be compared nvoCMPOut SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 nviCMPIn1 and nviCMPIn2 are compared OFF is output whe...

Страница 12: ...In2 SNVT_switch nviENIn3 SNVT_switch nviENIn4 SNVT_switch nv 116 nv 119 nv 100 nv 103 nv 104 nv 107 nv 108 nv 111 nv 112 nv 115 Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviEN...

Страница 13: ...NOut VALUE OFF OFF OFF OFF SCPTvalueDefinition 0 ON OFF OFF OFF SCPTvalueDefinition 1 OFF ON OFF OFF SCPTvalueDefinition 2 ON ON OFF OFF SCPTvalueDefinition 3 OFF OFF ON OFF SCPTvalueDefinition 4 ON O...

Страница 14: ...s the timer function With Invalid nvoTMROut is reset to the default status and the internal counter is reset nvoTMROut SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Timer output Configuration Properties Com...

Страница 15: ...ins on Set Invalid at nviTMRIn to turn nvoTMROut off Example Providing one shot output when nviTMRIn is turned on SCPTtimeout 0 One shot output delay time SCPTtimeout 1 Pulse width SCPTtimeout 2 800 1...

Страница 16: ...riables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nvi...

Страница 17: ...on or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATION...

Страница 18: ...X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoD...

Страница 19: ...4 X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1...

Отзывы: