COMPONENT IDENTIFICATION
Euro Type
Connector Terminals
RUN LED
4 5 6
1 2 3
ON
1
Input 1
Input 2
2 3 4 5 6 7 8
RUN
■
SIDE VIEW
■
FRONT VIEW
■
STATUS INDICATOR LED
RUN indicator
: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
■
SIDE DIP SW
• Input Range: SW1 through 8
Each channel independent
SW
RANGE
INPUT 1
INPUT 2
1
2
3
4
5
6
7
8
OFF OFF OFF OFF OFF OFF OFF OFF -40 – +40mA
ON OFF OFF OFF ON OFF OFF OFF -20 – +20mA
OFF ON OFF OFF OFF ON OFF OFF -1 – +1mA
ON
ON OFF OFF ON
ON OFF OFF 0 – 40mA
OFF OFF ON OFF OFF OFF ON OFF 0 – 20mA
ON OFF ON OFF ON OFF ON OFF 4 – 20mA (*)
OFF ON
ON OFF OFF ON
ON OFF 0 – 1mA
(*) Factory setting
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R5CON for detailed operation.
■
CHANNEL INDIVIDUAL SETTING
PARAMETER
AVAILABLE RANGE
DEFAULT SETTING
Zero Scale
-32000 to +32000
0
Full Scale
-32000 to +32000
10000
Bias [Zero Adj.]
-320.00 to +320.00
0.00
Gain [Span Adj.]
-32000 to +32000
1.0000