background image

MODEL: R30NCIE1

R30NCIE1 SPECIFICATIONS

ES-9020 Rev.6   Page 1/7

https://www.m-system.co.jp/

Remote I/O R30 Series

NETWORK MODULE

(CC-Link IE Field network)
Functions & Features
• Interchanges analog or discrete I/O signals with the
filedbus (CC-Link IE Field network)
• Combined with R3 Series I/O modules

98 [3.86]

110

[4.33]

25

[.98]

 mm [inch]

MODEL: R30NCIE1[1]

ORDERING INFORMATION

• Code number: R30NCIE1[1]
Specify a code from below for [1].
  (e.g. R30NCIE1/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

[1] OPTIONS

blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q

COATING (For the detail, refer to M-System's web site.)

/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

CAUTION

• The internal bus communication period for R3 series I/O
modules installed on the R30EBS is as follows.
Internal bus communication period = 6 msec. × number of
I/O 10 msec. (Data update period of main CPU)
    Example: Four R3 I/O modules
        6 msec. × 4 + 10 msec. = 34 msec.
Even when the R30EBS is mounted to the R30BS, the
internal bus communication period of R30 series is kept to
approx. 1 msec.

RELATED PRODUCTS

• PC configurator software (model: R30CFG)
• PC configurator software (model: R3CON)
Downloadable at M-System’s web site.
For connecting to PC, use commercially available Mini-B
type USB cable. (provided by user)
• R3 series I/O modules (except R3-TC2 and R3S-CM2A)

GENERAL SPECIFICATIONS

Connection
  CC-Link IE Field: RJ-45 connector
  Internal bus: Via the Installation Base (model: R30BS)
  Internal power: Via the Installation Base (model: R30BS)
Isolation: CC-Link IE Field to internal bus or internal power
Input type & range:
 R30 series I/O module: PC configuration software (model:
R30CFG)
 R3 series I/O module: PC configuration software (model:
R3CON)
 Network address: PC configuration software (model:
R30CFG)
Internal bus communication cycle: Approx. 1 msec.
Status indicator: RUN, RD, SD, D LINK, ERR, L ER, LINK
(Refer to the instruction manual.)

CC-Link IE Field COMMUNICATION

Protocol: IEEE 802.3
Transmission type: 1000BASE-T
Communication speed: 1 Gbps
Network cable: Cable conformed to CC-Link IE Field
Double shielded twist pair cable (CAT5e)
RJ-45 connector
Network topology: Line, star and ring
Max. number stations: 120 (Total slave station)
(Number of max. connectable slaves may vary depending
on the master module. Refer to the instruction manual of
the master module)
Max. station-to-station distance: 100 m
Station type: Remote device station
Link device: RX/RY 128 points, RWw/RWr 64 points

Содержание R30NCIE1

Страница 1: ...re model R30CFG PC configurator software model R3CON Downloadable at M System s web site For connecting to PC use commercially available Mini B type USB cable provided by user R3 series I O modules ex...

Страница 2: ...30BS Weight 125 g 0 28 lb PERFORMANCE Insulation resistance 100 M with 500 V DC Dielectric strength 1500 V AC 1 minute CC Link IE Field to internal bus or internal power 1500 V AC 1 minute power input...

Страница 3: ...R30YN16A 1 R30EBS04 1 R3 SV8 8 2 R3 YV8 8 3 R3 DA32A 2 4 R3 DC32A 2 0 15 RWr n 0 Slot 1 2 4 6 8 10 12 14 Slot 2 Slot 3 Slot 4 INPUT DATA The figure below shows the data sent from the device to the mas...

Страница 4: ...tus for each module of R3 series The bit corresponding to such module turns to 1 as described below When the each module is detached the error bit is held R3 TSx R3 RSx R3 US4 Input burnout R3 DA16A i...

Страница 5: ...is represented in 2 s complements ANALOG DATA 16 bit data models R30RS4 R30TS4 R30US4 etc 0 15 16 bit binary data With C temperature unit raw data is multiplied by 10 For example 25 5 C is converted i...

Страница 6: ...y data is used for BCD Lower 16 bits are allocated from the lowest address to higher ones higher 16 bits in turn 0 15 0 Lower 16 bits 0 15 1 Higher 16 bits 16 POINT DISCRETE DATA models R30XN16A R30YN...

Страница 7: ...ing CN1 and CN2 of RJ 45 connector for CC Link IE Field network there is no restriction for connection order INTERNAL BUS INTERNAL POWER RJ 45 MODULAR JACK RJ 45 MODULAR JACK USB CONNECTOR PC CONFIGUR...

Отзывы: