HOW TO CAPTURE POTENTIOMETER’S ZERO/SPAN

Particular positions of the potentiometer can be captured 
(stored in memory) as ZERO (0%) or SPAN (100%) points by 
manipulating Zero/Span Selector and UP/DOWN switches.

ZERO

:  Press DOWN switch and maintain.  Switch the Zero/

Span Selector to the bottom position and let go the 
DOWN switch.  Check that the status indicator LED 
which was blinking has turned ON.  Return the 
Zero/Span Selector to the middle position.  The sta-
tus indicator LED starts blinking again.

SPAN

:   Press DOWN switch and maintain.  Switch the 

Zero/Span Selector to the top position and let go 
the DOWN switch.  Check that the status indicator 
LED which was blinking has turned ON.  Return the 
Zero/Span Selector to the middle position.  The sta-
tus indicator LED starts blinking again.

I/O RANGE MODIFICATION

Configurator Software is used to change input range.
Output ranges can be changed over the described range of 
the selected suffix code with the Configurator Software.
For changing out of this range, set the Output Range Selec-
tors before software adjustment.

UP/DOWN Switches

The front cover cannot be turned open by 180 deg. 

when there is no extra space between units.

Configurator Jack

■ 

FRONT VIEW (with cover open)

Status Indicator LED

Zero/Span Selector

Top: SPAN

Middle: OFF

Bottom: ZERO

■ 

LEFT SIDE VIEW

    (with cover removed)

Output Range Selectors

[e.g.]
Output code V1

O

N

2

1

3

4

5

6

7

8

O N

2

1

3 4

SW2

ATT

SW3

SW6

SW4

SW7

I

V

I

V

• 

Output range selectors

SW2

SW3

1

2

3

4

V1

OFF

OFF

ON

ON

Not ATT

V2

OFF

OFF

ON

ON

Not ATT

Z1

ON

ON

OFF

OFF

Not ATT

SW4

1

2

3

4

5

6

7

8

V1

ON

ON OFF ON

ON

*

ON OFF

V2

ON OFF ON OFF ON

*

ON OFF

Z1

OFF OFF ON OFF OFF OFF OFF OFF

SW6

SW7

V

I

V

I

V1

ON

OFF

ON

OFF

V2

ON

OFF

ON

OFF

Z1

OFF

ON

OFF

ON

* ON/OFF position is irrelevant.

STATUS INDICATOR LED

The M2XM2 is provided with a status indicator LED which 
blinks in different patterns indicating various status of its 
CPU.
When it is functioning within normal parameters, the LED 
blinks in a regular pattern of ON and OFF.
When the unit is in an abnormality, it blinks in particular 
patterns repeating approximately in 1.3 seconds.
The following figure indicates typical patterns.  A white 
circle means that the light is OFF for 80 millisec., while a 
black one means ON for 80 millisec.

Running mode

Undefined functions

Program mode

Burnout

MAINTENANCE

Regular calibration procedure is explained below:

 

CALIBRATION

Warm up the unit for at least 20 minutes.  Apply 0%, 25%, 
50%, 75% and 100% input signal.  Check that the output 
signal for the respective input signal remains within accu-
racy described in the data sheet.  When the output is out 
of tolerance, recalibrate the unit according to the “ZERO/
SPAN ADJUSTMENTS” explained earlier.

LIGHTNING SURGE PROTECTION

M-System offers a series of lightning surge protector for 
protection against induced lightning surges.  Please contact 
M-System to choose appropriate models.