M-system Mastro ADA2001 Скачать руководство пользователя страница 6

1 - DIAGRAM

063_03

- GAS KITCHENS

6

· 22

03/2006

100 150

142

900

52

300

900

706

150

3/4" 

970

53

1600

53

1494

900

255

296

350

200

200

400

400

400

140

270

900

35

55

340

1600

21

21

3/4"

53

53

1494

6.0 kW    Ø 120 mm

7.8 kW    Ø 120 mm

9.5 kW    Ø 125 mm

AEA20004

AEA20004

ADA20009
ADA20010

7.8

kW

9.5

kW

7.8

kW

6.0

kW

7.8

kW

9.5

kW

9.5

kW

6.0

kW

ADA20004 - ADA20009 - ADA20010

3/4"

220

680

255

296

350

310

590

200

200

400

400

400

7.8

kW

9.5

kW

7.8

kW

6.0

kW

7.8

kW

9.5

kW

9.5

kW

6.0

kW

Содержание Mastro ADA2001

Страница 1: ...063_03 Instructions for installation use and maintenance 03 2006 GAS KITCHENS ADA2017 ADA2001 ADA2002 ADA2003 ADA2004 ADA2005 ADA2006 ADA2007 ADA2008 ADA2009 ADA2010 AEA2001 AEA2002 AEA2003 AEA2004...

Страница 2: ...CHARACTERISTICS 063_03 GAS KITCHENS 2 22 03 2006 Supplied by Date Customer Service FAX e mail...

Страница 3: ...e of gas ovens GN 1 1 and MAXI 13 5 1 17 Replacement of burner nozzle gas oven 13 5 2 Maintenance 13 5 3 Replacing parts 14 5 3 1 Gas valve open flames 14 5 3 2 Thermocouple open flames 14 5 3 3 Plug...

Страница 4: ...200 200 295 350 310 590 3 4 100 150 142 900 52 300 900 706 150 3 4 970 400 53 21 53 294 3 4 AEA20002 ADA20001 ADA20001 AEA20001 AEA20002 ADA20006 ADA20005 ADA20002 ADA20005 ADA20006 800 694 53 53 21...

Страница 5: ...W 120 mm 7 8 kW 120 mm 9 5 kW 125 mm 1200 53 53 1094 270 900 35 55 340 900 255 296 350 200 200 400 400 140 AEA20003 AEA20003 ADA20007 ADA20008 ADA2017 9 5 kW 6 0 kW 7 8 kW 9 5 kW 9 5 kW 6 0 kW ADA2000...

Страница 6: ...00 400 400 140 270 900 35 55 340 1600 21 21 3 4 53 53 1494 6 0 kW 120 mm 7 8 kW 120 mm 9 5 kW 125 mm AEA20004 AEA20004 ADA20009 ADA20010 7 8 kW 9 5 kW 7 8 kW 6 0 kW 7 8 kW 9 5 kW 9 5 kW 6 0 kW ADA2000...

Страница 7: ...m LxDxH 400 x 900 x 900 970 400 x 900 x 270 340 800 x 900 x 900 970 800 x 900 x 270 340 1200 x 900 x 900 970 1200 x 900 x 270 340 1600 x 900 x 900 970 1600 x 900 x 270 340 800 x 900 x 900 970 800 x 90...

Страница 8: ...c oven power GN 2 1 5 9 kW GN 1 1 2 5 kW Voltage V AC 400 3N 50 Hz AC 230 3 50 Hz AC 230 50 Hz No of cables per section 5 x 2 5 mm2 4 x 2 5 mm2 3 x 1 5 mm2 Open Open Gas oven GN 1 1 7 5 3 6 0 75 155 A...

Страница 9: ...an be varied between 160 and 300 C is made with the thermostat The bottom of the oven in cast iron with reinforced ribs for GN 2 1 and steel for MAXI is in two pieces The smoke collector is in alumini...

Страница 10: ...h Conversion and adaptation 4 3 2 Statutory regulations and technical requirements During installation of the appliance the following regulations must be adhered to Relevant legal directives Local bui...

Страница 11: ...perating calorific value 5 1 6 Check of pilot flame For proper regulation the pilot flame must surround the thermo couple and it must have a perfect appearance Otherwise adjust the air flow to the pil...

Страница 12: ...5 SET UP FOR OPERATION 063_03 GAS KITCHENS 12 22 03 2006 18 6 14 16 15 3 9 19 2 Fig 2B A 15 14 2 9 19 11 12 13 17 3 4 16 18 Fig 2A 18 14 12 13 11 16 3 9 19 2 Fig 2C...

Страница 13: ...move the nut 11 slide out the bicone 13 and the injector 12 Replace the injector 12 see the table TECHNICAL DATA and replace all parts in reverse order 5 1 16 Replacement of pilot nozzle for gas oven...

Страница 14: ...eating element is placed under the bottom The upper heating element is attached to the top of the cooking chamber To remove the heating elements loosen the screws that attach them to the corresponding...

Страница 15: ...nge the product as he see fits though without changing its essential features The manufacturer declines all responsibility for any non compliance with the provisions contained in this manu al 6 2 Star...

Страница 16: ...upper part of the oven As in the previous position with the fan on convection In this position the top heating element from above and the bottom heating element from below are on and at the same time...

Страница 17: ...at The inactive layer can be chemically damaged or jeopardized by reducing agents oxygen consumption if they come in contact with the steel concentrated or at high temperatures These active sub stance...

Страница 18: ...the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall resul...

Страница 19: ...ECTRICAL DIAGRAMS 063_03 GAS KITCHENS 19 22 03 2006 RG RS RV MV T Grill heating element Bottom heating element Fan heating element Motorized fan Thermostat A C R G RC Terminal board Commutator Green i...

Страница 20: ...0 V 3 14 75 A 1 3 5 2 4 6 R1 R2 230 V 25 7 A 1 3 5 2 4 6 R1 R2 L1 N 1 mA 2 3 4 1 mA 2 3 4 L1 L2 L3 7 APPENDIX ELECTRICAL DIAGRAMS 063_03 GAS KITCHENS 20 22 03 2006 H1 H2 R1 2 F2 Indicator light power...

Страница 21: ...7 APPENDIX ELECTRICAL DIAGRAMS 063_03 GAS KITCHENS 21 22 03 2006 mA B1 MV H2 Terminal board Fan switch Motorized fan Indicator light mA B1 F1 F2 H1 H2 R1 R2 Terminal board Switch Thermostat Temperatur...

Страница 22: ...THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HE...