background image

M6DXAT

P.  / 4

EM-7854 Rev.

INSTALLATION

Set the unit so that its DIN rail adapter is at the bottom.  
When the unit is installed to an Installation Base (model 
M6DBS), refer to its instruction manual.

 

 MOUNTING THE UNIT ON A DIN RAIL

A) Hang the upper hook at the rear side of unit on the DIN 

rail.

B) Push  in  the  lower  in  keeping  pressing  the  unit  to  the 

DIN rail.

 REMOVING THE UNIT

A) Pull  down  the  DIN  rail  adaptor  using  a  minus  screw-

driver.

B) Pull out the lower part of the unit.
C) Remove the upper part from the DIN rail.

DIN Rail

A

B

DIN Rail Adaptor

A

B

C

COMPONENT IDENTIFICATION

Body

Front Cover

DIN Rail Adaptor

Spec. Marking

Status Indicator LED

Configurator Jack

Power LED

Alarm Monitor LED

 FRONT VIEW (with the cover open)

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание M6D Series

Страница 1: ...types GENERAL SPECIFICATIONS Connection Input and output Euro terminal torque 0 3 N m Power input Via the Installation Base model M6DBS or Euro terminal torque 0 3 N m Applicable wire size 0 2 to 2 5...

Страница 2: ...C 0 006 F of max span Response time 0 5 sec 0 100 at 90 setpoint Burnout response time 1 sec Line voltage effect 0 1 over voltage range Insulation resistance 100 M with 500 V DC Dielectric strength 20...

Страница 3: ...k Power LED Alarm Monitor LED DIMENSIONS unit mm inch 94 3 70 5 9 23 DIN RAIL HOOK 102 4 02 0 5 02 8 M3 EURO TERMINAL DIN RAIL 35mm wide 5 6 7 8 1 2 3 4 When mounting no extra space is needed between...

Страница 4: ...uctive Load Coil Diode Varistor or CR Circuit POWER OUTPUT Ry CONFIGURATOR JACK STATUS LED ALARM MONITOR LED Digital Computation T C comp leadwire CJC SENSOR CONNECTOR POWER POWER LED Specifications a...

Страница 5: ...such that appropriate clearance and creepage distances are maintained to con form to CE requirements Failure to observe these re quirements may invalidate the CE conformance POWER INPUT RATING OPERATI...

Страница 6: ...to the DIN rail REMOVING THE UNIT A Pull down the DIN rail adaptor using a minus screw driver B Pull out the lower part of the unit C Remove the upper part from the DIN rail DIN Rail A B DIN Rail Adap...

Страница 7: ...L DIN RAIL 35mm wide 5 6 7 8 1 2 3 4 When mounting no extra space is needed between units WIRE INSERTION ANGLE approx 7 SCREWDRIVER INSERTION ANGLE approx 40 2 4 3 NC NO COM 5 6 OUTPUT POWER CONFIGURA...

Страница 8: ...xplained below CALIBRATION Warm up the unit for at least 10 minutes H Setpoint Increase the input signal from a value lower than the set point and check that the relay trips at the H setpoint within t...

Отзывы: