manualshive.com logo in svg
background image

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-2776  P. 1 / 4

INSTRUCTION MANUAL

PEAK HOLD

(PC programmable)

MODEL

M5XPHS

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Signal conditioner ...............................................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.
The M5XPHS is programmable using the PC Configurator 
Software.  For detailed information on the PC configuration, 
refer to the M5CFG users manual.  The M5CFG PC Con-
figurator Software is downloadable at M-System’s web site: 
https://www.m-system.co.jp

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    24V DC rating: 24V ±10%, ≤ 1W

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -20 to +65°C 

(-4 to +149°F) with relative humidity within 30 to 90% 
RH in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Install lightning surge protectors for those wires connect-

ed to remote locations.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

Terminal Cover

Power Indicator LED

Configurator Jack

Body

Specification

Output Setting DIP SW

Input Setting DIP SW

(side)

Содержание M5XPHS

Страница 1: ... may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V 10 1W GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and inpu...

Страница 2: ... Pull down the DIN rail adaptor using a minus screwdriv er B Pull out the lower part of the unit C Remove the upper part from the DIN rail A Slider C B TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 94 3 70 3 12 25 98 41 1 61 3 3 13 When mounting no extra space is needed between units DIN RAI...

Страница 3: ... a higher signal or a command to reset is received VALLEY HOLD MODE The transmitter output responds only to a decreasing signal holding the minimum value until a lower signal or a command to reset is received PEAK TO PEAK HOLD MODE The transmitter output responds only when the input signal goes over the previously monitored maximum value or goes below the previously monitored minimum value The out...

Страница 4: ... 0 100 of the full scale When the output does not track the input signal check that the terminals 3 4 shortcircuited or open is match to the setting 5 Output Check that the load resistance meets the de scribed specifications POWER INDICATOR LED The transmitter is provided with a power indicator LED which blinks in different patterns indicating various oper ating status The following figure indicat...

Отзывы: