CLAMP-ON CURRENT SENSOR (screw terminal type CLSB)

Connection

:   M3 screw terminal

     

 

 

(nickel-plated steel; torque 0.5 N·m)

• 0 – 10A through 0 – 50A Use

Sensor model No.

: CLSB-05

Applicable cable diameter

: Max. 10.0

Weight

: 45 g (1.6 oz)

k

k

l

l

28.9 (1.14)

26.3 (1.04)

8.6

(.34)

8.6

(.34)

48 (1.89)

10 dia. (.39)

2–M3 SCREW

TERMINAL COVER
(detachable)

K

L

• 0 – 60A through 0 – 100A Use

Sensor model No.

: CLSB-10

Applicable cable diameter

: Max. 16.0

Weight

: 80 g (2.8 oz)

37.4 (1.47)

30.5 (1.20)

7.5

(.30)

7.5

(.30)

53.7 (2.11)

16 dia. (.63)

2–M3 SCREW

k

k

l

l

TERMINAL COVER
(detachable)

K

L

• 0 – 125A through 0 – 200A Use

Sensor model No.

: CLSB-20

Applicable cable diameter

: Max. 24.0

Weight

: 200 g (7.1 oz)

k

k

l

l

2–M3 SCREW

55.9 (2.20)

35.9

(1.41)

8.3

(.33)

8.3

(.33)

75.7 (2.98)

24 dia. (.94)

TERMINAL COVER
(detachable)

K

L

• 0 – 225A through 0 – 400A Use

Sensor model No.

: CLSB-40

Applicable cable diameter

: Max. 35.0

Weight

: 300 g (10.6 oz)

35 dia. (1.38)

k

k

l

l

2–M3 SCREW

K

L

73.5 (2.89)

35.5

(1.40)

8.8

(.35)

8.8

(.35)

93 (3.66)

TERMINAL COVER
(detachable)

• 0 – 500A through 0 – 600A Use

Sensor model No.

: CLSB-60

Applicable cable diameter

: Max. 35.0

Weight

: 360 g (12.7 oz)

73.5 (2.89)

35.5

(1.40)

8.8

(.35)

8.8

(.35)

93 (3.66)

TERMINAL COVER
(detachable)

35 dia. (1.38)

k

k

l

l

2–M3 SCREW

K

L

Note 1:  The output values may vary depending on the accuracy 

of engagement at the clamp connection.

Note 2: The sensor is detachable up to 100 times (approx.).
Note 3:   The sensor’s mechanical construction may cause it to 

generate resonance sound.  However, it does not affect 
the performance of the sensor.

 

CONNECTION DIAGRAM

+

OUTPUT

5

6

3

4

8

7

U(+)

V(–)

POWER

LOAD

SOURCE

CONNECTOR

*

k

l

CLAMP-ON SENSOR

*

Connector provided only for the CLSA-08 and CLSA-12.

(A)

(±)

Содержание M5CTC

Страница 1: ...o physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 0 to 90 RH in order to ensure adequate life span and operation WIRING Do not install cables close to noise sources relay drive cable high frequency line etc Do not bind these cables together with those in which noises are present Do not install them in the same duct Install lightning surg...

Страница 2: ...pplicable cable diameter Max 10 0 Sensor leadwire AWG 22 Weight 45 g 1 6 oz L K 10 39 dia 41 1 61 23 91 27 1 05 26 1 02 150 5 91 3000 118 l k 0 100A Use Sensor model No CLSA 12 Sensor cable model No CLSA 08C 30 Applicable cable diameter Max 16 0 Sensor leadwire AWG 22 Weight 70 g 2 5 oz 16 63 dia 44 5 1 75 29 1 14 30 1 18 31 1 22 150 5 91 l k L K 3000 118 0 125A through 0 300A Use Sensor model No ...

Страница 3: ...g 7 1 oz k k l l 2 M3 SCREW 55 9 2 20 35 9 1 41 8 3 33 8 3 33 75 7 2 98 24 dia 94 TERMINAL COVER detachable K L 0 225A through 0 400A Use Sensor model No CLSB 40 Applicable cable diameter Max 35 0 Weight 300 g 10 6 oz 35 dia 1 38 k k l l 2 M3 SCREW K L 73 5 2 89 35 5 1 40 8 8 35 8 8 35 93 3 66 TERMINAL COVER detachable 0 500A through 0 600A Use Sensor model No CLSB 60 Applicable cable diameter Max...

Страница 4: ...e output as explained in the following HOW TO CALIBRATE THE OUTPUT SIGNAL Use a signal source and measuring instruments of sufficient accuracy level Turn the power supply on and warm up for more than 10 minutes 1 ZERO Apply 10 input and adjust output to 10 2 SPAN Apply 100 input and adjust output to 100 3 Check ZERO adjustment again with 10 input 4 When ZERO value is changed repeat the above proce...

Отзывы: