Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Clamp-on pulse sensor ........................................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

POWER INPUT RATING & OPERATIONAL RANGE

• 

Locate the power input rating marked on the product and 
confirm its operational range as indicated below:

    12V DC rating: 12V ±10%, max. 5mA

 

GENERAL PRECAUTIONS

• 

Before you remove the module or mount it, turn off the 
power supply and input signal for safety.

 

ENVIRONMENT

• 

Indoor use.

• 

When heavy dust or metal particles are present in the air, 
install the module inside proper housing with sufficient 
ventilation.

• 

Do not install the module where it is subjected to continu-
ous vibration.  Do not subject the unit to physical impact.

• 

Environmental temperature must be within 0 to 55°C (32 
to 131°F) with relative humidity within 80% RH in order 
to ensure adequate life span and operation.

 

WIRING

• 

Do not install cables close to noise sources (relay drive 
cable, high frequency line, etc.).

• 

Do not bind these cables together with those in which 
noises are present.  Do not install them in the same duct.

 

AND ....

• 

The module is designed to function as soon as power is 
supplied, however, a warm up for 10 minutes is required 
for satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

Terminal Cover

(separable)

Specifications

*

*

Binding strap here

*

Tab

Body

Input Cable

Lever

Top Section

INSTALLATION

 

MOUNTING THE MODULE

1) Remove the terminal cover and connect wires according 

to the connection diagram.  Be aware of the wire inser-

tion direction (See ‘Inserting Wires’).

2) Put the terminal cover back so that its keys meet the key 

holes.  Be aware of the cover direction.

R1

R0

12V

Terminal Cover

Key

Terminal Cover

Key Hole

Mounting Hole

3) Tighten screws using the mounting holes to fix the mod-

ule on a wall.

 

CONNECTING THE INPUT CABLE

1) Squeeze the levers on both sides to detach the tabs and 

pull out the top section.

2) Place the input cable to the position indicated on the 

above drawing.

3) Put back the top section and bind over the tabs/levers  

with a binding strap.

CLAMP-ON PULSE SENSOR

MODEL

CLSP

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9237  Rev.3  P. 1 / 2