109
A
IR VENT NECESSARY FOR GAS COMBUSTION
=
(2 m
3
/h x kW)
BURNERS
Air vent necessary [m
3
]
Auxiliary (A)
2,00
Semirapid (SR)
3,50
Rapid (R)
6,00
Triple-ring (TC)
7,00
LUBRICATION OF THE GAS TAPS
– In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be
fulfiled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
G30/G31
G 20/G 25
BURNERS
28-30/37 mbar
20/25 mbar
Auxiliary (A)
1,00
0,30
27
50
72 (X)
Semi-rapid (SR)
1,75
0,45
32
65
97 (Z)
Rapid (R)
3,00
0,75
42
85
115 (Y)
Triple-ring (TC)
3,50
1,50
65
95
135 (T)
TABLE FOR THE CHOICE OF THE INJECTORS
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
adjustable
FR
Cat:
II
2E+ 3+
BE