INSTALLATION

Detach the yellow clamps located at the top and bottom of 
the unit for separate the body from the base socket.

Clamp

(top & bottom)

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Shape and size of the base socket 
are slightly different with various 
socket types.

 

DIN RAIL MOUNTING

Set the base socket so that its 
DIN rail adaptor is at the bot-
tom.  Hang the upper hook at 
the rear side of base socket on 
the DIN rail and push in the 
lower.  When removing the 
socket, push down the DIN 
rail adaptor utilizing a minus 
screwdriver and pull.

 

WALL MOUNTING

Refer to “EXTERNAL DI-
MENSIONS.”

TERMINAL CONNECTIONS

Connect the unit as in the diagram below or refer to the connection diagram on the top of the unit.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

5

6

7

8

2

1

11

10

80 (3.1

5)

50 (1.97)

107 (4.21)

136 (5.35)

[3.3 (.13)]

80 (3.1

5)

20 (.79)

40 (1.57)

50 (1.97)

7.8 (.31)

CLAMP

(top & bottom)

DIN RAIL

35mm wide

2

4.5 (.18) dia.

MTG HOLE

25 (.98) deep

11

M3.5

SCREW

• When mounting, no extra space is needed between units.

3

9

4

 

CONNECTION DIAGRAM

V(–)

7

8

POWER

U(+)

4

5

6

H

L

C

SETPOINT 1 

OUTPUT

H

L

C

SETPOINT 2 

OUTPUT

*

Relay status for output codes “1” & “4”, at power OFF.

*

*

10

9

3

2

1

11

red

yellow

white

Angle

Sensor

(model: NRA)

EXC.

INPUT

COM

ANR

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-2116  P. 2 / 3