manualshive.com logo in svg
background image

20VS1D

P. 2 / 2

EM-4431

APPLICATION EXAMPLE

22

21

20

19

V

REF

V

OUT

R1

R2

IC1

IC2

R3

10kΩ

R4

6.08kΩ

+

+

+

INPUT V

IN

To adjust zero and span, use top adjusters.
For input 1-5V DC, output is 4-20mA DC.
In order to shift the zero at input, supply reference voltage 
to pin 21.  The following formula shows how much the zero 

shifts.  (input signal at pin 20 = V

IN

; output signal at pin 1 = 

V

OUT

; reference voltage = V

REF

; zero shift = V

OUTSHIFT

.)

     

           10kΩ

V

OUTSHIFT

 = - (––––––) 

× 

V

REF

     

             R1

    

 (10kΩ+R1)

V

OUT

 =  ––––––––– 

× 

V

IN + 

V

OUTSHIFT

     

      R1

In order to attenuate input signal, connect a resistor to pin 
22.  The following formula shows the attenuated output.
     

 

    

R2

V

OUT

 = (––––––––––––) 

× 

V

IN

     

  R2 + 6.08 k

Ω

External  resistors  and  adjusters  make  zero  and  span  ad

-

justment available.

M-SYSTEM WARRANTY

M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such 
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive 
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this 
warranty.  To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original 
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR 
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

 PIN ASSIGNMENT

NO.

FUNCTION

1

Current Output (+)

2

Current Output (-)

3

NC

4

NC

5

NC

6

NC

7

Excitation (+)

8

Excitati

on (-)

9

Excitation (COM)

15

Power Supply (+)

16

Power Supply (-)

17

Synchronous Input

18

Synchronous Output

19

Input (-)

20

Input (+)

21

Input Amplification

22

Input Attenuation

33

NC

34

NC

35

NC

36

NC

CHECKING

1)  Terminal wiring: Check that all cables are correctly con-

nected according to the connection diagram.

2)  Power input voltage: Check voltage across the pins.
3)  Input: Check that the input signal is within 0 – 100% of 

the full-scale.

4) Output: Check that the load resistance meets the de-

scribed specifications.

ADJUSTMENT PROCEDURE

This unit is calibrated at the factory to meet the ordered 
specifications, therefore you usually do not need any cali-
bration.

For matching the signal to a receiving instrument or in case 
of regular calibration, adjust the output as explained in the 

following.

 HOW TO CALIBRATE THE OUTPUT SIGNAL

Use a signal source and measuring instruments of sufficient 
accuracy level.  Turn the power supply on and warm up for 
more than 10 minutes.

1)  ZERO:  Apply 0% input and adjust output to 0%.
2)  SPAN:  Apply 100% input and adjust output to 100%.
3)  Check ZERO adjustment again with 0% input.
4)  When  ZERO  value  is  changed,  repeat  the  above  proce

-

dure 1) – 3).

MAINTENANCE

Regular calibration procedure is explained below:

 CALIBRATION

Warm up the unit for at least 10 minutes.  Apply 0%, 25%, 

50%, 75% and 100% input signal.  Check that the output 
signal for the respective input signal remains within accu-
racy described in the data sheet.

Отзывы: