M-SURE Digital Height Gaug
e User Man
ual
Trouble Shooting
Metric/Inch Conversion
25.40
mm
mm/inch
Press mm/inch to convert
from metric to inch display.
1.000
The display will indicate
which units are being
displayed.
mm/inch
in
Zero Height Gauge
0.00
mm
ZERO
Press ZERO to clear.
Problem
Possible Cause
Solution
Flashing display
Low voltage
Poor contact
Replace battery
Clean contact
No display
Dead or weak battery
Poor contact
Replace battery
Clean contact
Erratic or frozen display
Contamination between beam & head
Low voltage
Wipe clean
Replace battery
Erroneous reading
Low voltage
Contamination between beam & head
Too much operating force
Low ambient temperature
Scriber loose
Scriber mating faces are dirty
Replace battery
Wipe clean
Use pressure device
Store at normal room temperature
Ensure scriber is clamped correctly
Clean mating faces
Height Gauge with ABS Function
(not available on all models)
30.00
mm
Measure workpiece,
for
example 30mm.
20.00
mm
ABS
Press ABS button to switch to
incremental. Measure second
workpiece,
for example 50mm.
50.00
ABS
Press ABS to switch back to
Absolute display.
mm
ABS