background image

5

www.m-locks.com

Rotobolt

V03

EN

BOLTWORK REQUIREMENTS

The force applied to the boltwork on the lock bolt has to be limited to 1 kN (p. E. by a preconceived 
breaking point). Please contact your manufacturer if higher forces are needed. Only use supplied 
screws to mount the lock.

The maximum allowed cable/spindle-hole diameter is 11mm (if located 
under the lock body)
If the Rotobolt lock is used in conjunction with another lock, the boltwork 
must be constructed in a way that the Rotobolt secures first.

In the LOCKED position the distance between the Rotobolt bolt and the bolt-
work part that is moving the lock bolt should be approximately 1 mm. 

Only use supplied screws to mount the lock. Tighten the screws securely so 
the lock body is attached firmly to the mounting surface.
(Maximum Torx 5, 5 Nm)

  

 

MOUNTING INSTRUCTIONS

Mount the entry unit following the manufacturer’s instruction.

Insert the connector of the entry unit in the 
outer (ENT) position.  Connect battery / alarm 
box connector (if used) in the inner (BAT) 
position. Check that the connector(s) is com-
pletely seated.  

To remove the connector(s), carefully lift and 
pull it out.

Connect a 9V alkaline Duracell , Energizer or Duracell Industrial battery to the battery clip to  the 
keyboard (or battery box) , and check the lock functions . Keep the cable from sharp edges or moving 
boltwork parts and set permanently .