10
LPG SYSTEM
If an LPG system is installed in this craft you must
(D)
:
1) Close fuel supply-line valves and cylinder valves when appliances are not
in use. Close valves before refueling and immediately in an emergency.
2) Be sure that appliance valves are closed before opening the cylinder valve.
3) Test the LPG system for leakage regularly. Check all connections for
leakage by
- routine observation ob the bubble-leak detector (if fitted with a detector),
- observation of the pressure gauge for pressure drop with appliance valves
closed and cylinder valve opened, then closed (if bitted with gauge on supply
pressure side),
- manual leak testing, or testing with soapy water or detergent solution (with
appliance-burner valves closed and cylinder and system valves open).
If leakage is present, dose the cylinder valve and have the system
repaired before further use. System repairs should be made by a competent
person.
4) Never use solutions containing ammonia.
5) Never use flame to check for leaks.
6) Remember that fuel-burning open-flame appliances consume cabin
oxygen and release products of combustion into the craft. Ventilation Is
required when appliances are in use. Open designated vent openings while
appliances are in use. Do not use the stove or oven for space heating. Never
obstruct ventilation openings.
7) Follow all the information in order to prevent risks of fire explained in this
manual.
8) Never obstruct access to LPG system components in any way.
9) Keep valves on empty cylinders closed and disconnected. Keep protective
covers, caps or plugs in place. Store reserve cylinders in ventilated housings
on open decks or in gastight lockers which are vented overboard and
intended for that purpose.
10) Store gas cylinders only in the designed locker or housing and never use
LPG cylinder housings or cylinder lockers for storage of any other equipment.
11) Never leave craft unattended when LPG consuming appliances are in
use.
12) Never smoke or use open flame when replacing LPG cylinders.
13) Inspect hoses in LPG system regularly, and replaced if any deterioration
is found.
14) Inspect fuel pipes at least annually. Replace if deterioration or openings
are found.
15) Never use the stove when high angle of rolling or sustained angles of
heel are likely (if the craft is not equipped with a gimbaled stove).
Содержание Europa Sport