MINIMUM HEIGHT OF THE FLUE IN TERMS OF REDUCTIONS
ø 250
ø 200
ø 180
Venus 700
≥ 4m
Venus 850 / 850 D
≥ 4m
≥ 6m
Venus 1000
≥ 4m
≥ 6m
Venus 630
≥ 4m
≥ 6m
Venus 730
≥ 4m
≥ 6m
Venus 850 D
≥ 4m
≥ 6m
I
f no possibility to have external air inlet from outside or from a shelter
, you can install the appliance. But !
You have to connect the air inlet 100 mm with a tube to a grill in the masonry. In this way you will provide the Venus
Green Plus with Oxygen coming in from the living room. Please keep this livingroom adequately ventilated to avoid
under pressure. This type of installation is not advised for Passive houses. ( As same for installation with fan in this
way)
Never use a 90 degree bend ! the angle of the bend must exceed 45 degrees
with the perpendicular. Per 45 degree change of direction ( 2 curves 45 ), install
1 m more regarding this table.
With fan, but without possibility to provide external air inlet from
outside
Without fan, but without possibility to provide external air inlet from
outside
Guarantee ceased to be valid if the instructions and guidelines of these operating
intructions were not followed.
This is only a Quick Start document. Please, read carefully our Installation Guide
Venus 850 D
: Fan not available
Convection Inlet grill
Air inlet for combustion
Convection Inlet grill
Air inlet for combustion
Fan requires 200 cm²
vent from room
convection inlet !