Now that installation is complete, the unit can be built in.
Before starting work, first check the gas tightness.
Start the fireplace and check its operation, the tightness of the gas pipes and the exit of the
combustion gases. If these are in order, you can start the insulation and finishing work. The
integrated part of the chimney becomes very hot. Therefore, make sure that the fireplace
is not too narrow, but that there is enough room to extract hot air.
Masonry should be erected around the fireplace with a minimum distance of 4 cm between
the fireplace and the finish. It is forbidden to put bricks or any other material on the fire
-
place. IT MUST BE TOTALLY DETACHED FROM ALL MATERIALS.
5. INSLATION AND FINISHING
6. CONVECTION
When installing the fireplace, a hot air outlet must be placed at the top left and right of the
cabinet to dissipate heat in the area where the fireplace is located.
This is important for cooling the chimney in the chimney. There are no flexibles to install
with True Vision Rustica.
Do not isolate the device! Do not use glass wool or rock or other types of insulating materi
-
als (PVC, plaster, foam, ...). These cause fading and also annoying odors via the convection
outlets. Never leave rubbish near the fireplace in the area where it is built in!!