Optimal operation
Optimal use of fuel and optimal operation of the stove reach loading cca.3,5kg of the wood per hour
(3pieces cca.50cm long), lying horizontal on the raft in the middle of the combustion room. The chimney effect
12-15Pa and the regulator supply air open 30%.
1.2.2
Forbidden fuel
The use of treated wood /painted, etc./ and all types of household waste, which can disperse hazardous
gases, is FORBIDDEN and CANCELS OUT ANY CLAIM ON THE GUARANTEE. The use of fluid fuel
/petrol, etc. / is also FORBIDDEN.
1.3
STARTING THE FIRE
Regulation at maximum /see Pic.5/
Open the door /Pic.4 /.
Put a bed of tinder (paper or firelighters) with a little kindling (small twigs or pieces of wood) in the
stove and light the tinder. Let the door a little open /+3cm/, so as chimney effect arose, which helps the
kindling start the fire.
After the kindling has caught fire and burns well, the logs maybe placed on the fire. When the logs are
burning, the door can be closed.
NOTE: When a fire is made for the first time, the paint will harden and that give off smoke and a smell,
which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes. See to it that
there is ample ventilation in the room. The combustion chamber should be kept closed except for fuelling
to prevent entry of gases into the room.
CAUTION:
It is not necessary to overload the fireplace with wood. 1kg dried wood gices a 4kW power.
Example: a fireplace with 80% return gives a power for about 3,2kW for 1kg dry wood. If you want
a power about 6-7kW, it is just enough to put 2kg wood in the fireplace. This is like two normal pieces of
wood. We are not responsible for the wrong use of fireplace and any consequence for not following this
guideline. External surfaces of the stove are hot during operation, which has to be paid due attention to
avoid an accident burns.
2
INSTALLATION
2.1
INSTALLATION
For your own safety and satisfaction, we advise you to entrust specialist with the installation.
The
appliance has to be installed according to certain prescribes rules and local regulations.
The device must be
built in an area with an adequate capacity, on the board, which can spread the weight of the device. The device
max
min
Pic.5